Datasheet
Product Information
Protective Vents
adhesive vents
snap-in series
• Install on a flat, vertical housing
surface where water or other
contaminants will not pool.
• Attach the vent on the outside
of the housing.
Environmental
Performance
GORE
®
Vents Snap-In Series have been tested by
independent laboratories and have been verified
to meet these performance standards.
All certificates are available upon request.
Vent durability in hot,
humid environments
(accelerated aging test)
Method:
• IEC 60068-2-78
Test conditions:
n
85 °C
n
85% relative humidity
n
1,000 hours
Humidity Testing
Product Name
PolyVent Supra PolyVent InSet
PolyVent Standard PolyVent High Airflow
Product Number
VE0006GSV
PMF200271
PMF200128 PMF200484 PMF200521
Product Performance Characteristics
Typical airflow 35 ml / min (dp = 70 mbar) 200 ml / min (dp = 70 mbar)
450 ml / min (dp = 70 mbar) 2500 ml / min (dp = 70 mbar) 2000 ml / min (dp = 70 mbar)
Laminate: membrane / backing material ePTFE / Polyester (PET) ePTFE / – ePTFE / Polyester (PET) ePTFE / Polyester (PET) ePTFE / Polyester (PET)
Membrane characteristic Oleophobic Oleophobic Oleophobic Hydrophobic Oleophobic
Vent body & cap: material
Silicone Outer hull: Silicone
/
Carrier ring: PA
Polybutylene Terephthalate (PBT) Polybutylene Terephthalate (PBT) Polybutylene Terephthalate (PBT)
Vent body & cap: color Black Outer hull: clear / Carrier ring: black Black (similar to RAL 9004) Black (similar to RAL 9004) Black (similar to RAL 9004)
O-ring material – – EPDM 50 Shore A EPDM 50 Shore A EPDM 50 Shore A
Installed height (to the inside)
1.5 mm 1.4 mm
2.9 mm 2.9 mm 2.9 mm
Installed height (to the outside)
1.5 mm
0.0 mm (when inside-mounted) 5.7 mm 5.7 mm 5.7 mm
Traceability No No Yes: Individually laser-marked Yes: Individually laser-marked
Yes: Individually laser-marked
Design and Dimensions
Units are in mm
Recommended Installation
Units are in mm
• Install on a flat, vertical housing surface where
water or other contaminants will not pool.
• Install vent with cap on exterior of housing.
• New PolyVent InSet is designed to be mounted from
inside the enclosure. (It can also be mounted from
outside, but inside-mounting is recommended.)
GORE
TM
Membrane
1.5
O / 11
O / 13.7
0.25
6.8
0.25
O / 8.5
0.1
2 0.1
Housing wall
Housing wall
O / 12
min: 5.8
0.1
Rz 8 - 12
min: 0.8
max: 4.0
min: 0.1
Vent durability in a range
of temperatures
Methods:
• IEC 60068-2-1
(to -40 °C)
• IEC 60068-2-2
(to +125 °C)
• IEC 60068-2-14
(cycling: -40 °C to 125 °C)
Temperature Testing
Ingress Protection
Testing
Vent protection against ingress of
particulates and water
Method:
• IEC 60529
n
IP65 (PolyVent Supra only)
n
IP66 (PolyVent InSet, Standard
and High Airflow only)
n
IP67
n
IP68 (extended immersion:
2 meters for 1 hour)
n
IP69k (PolyVent Standard
and High Airflow only)
GORE
TM
Membrane
6.9
5.5
O / 12.5
0.2
O / 12.9
0.2
NEW
p p p