Specification and User Manual - 20210906

Power Supply
Power Consumption
Illumination
Dimensions (L*W*H)
Module: 103mm x 33mm x 22mm
Weight
Interface
Conformity
Working/Storage Temperature
Development Environment
Operation System
3.2 Electrical Specifications
3.2.1 Recommended Operating Conditions
Parameter
Symbol
Conditions
Min
Typ.
Max
Units
Supply voltage on USB
VBUS
VDD
4.75
5
5.25
V
Supply voltage on DC
power
VDC
5
5.5
6
V
Operating Temperature
Ta
-20
50
°C
Operating humidity
20
80
%
Storage humidity
20
80
%
Storage temperature
-30
70
°C
*: Please consider Vf range is about 1.3V
3.2.2 Power Consumption
Parameter
Conditions
Average
Max
Units
Current at
range0 mode
250mm-1200mm
@30 frame
468
769
mA
Current at
range1 mode
500mm-2600mm
@30frame
512
1011
mA
Current at
range2 mode
800mm-4400mm
@30frame
639
1394
mA
Note: 5V input voltage