6.4 Product State Machine
Power Off: product do not have any power
Broadcast: broadcast IP address, socket have not connected
Connected: socket is connected, product can transfer image and answer
host command
Factory Reset: resume all data to factory setting
TOF Driver Upgrade: product is in upgrading of TOF driver
System Upgrade: product is in upgrading of firmware
6.5 Software Command Set
DCAM560C support different work mode like depth_30, IR_30, depth&IR_30.
Four default ranges: range0(0.35m~1.5m), range1(0.5m~2.8m), range2(0.8m~4.4m),
range5(1.2m~6.0m).
User can use Frameviewer to try the different command or can use the APIs to control
the camera. The details please reference the SDK documents.
.