User's Manual

Vyyo Installation Guide
www.vyyo.com
Setting the WMTS IP Address – p. 93
Chapter 7. Setting the WMTS IP
Address
Note: Prior to performing this procedure the WMTS must
be connected to the “download” computer serial port via
the lower COM port (COM2) on the WMTS Control and
Forward card.
The WMTS must also be connected to the same LAN
subnet as the computer using its RJ45 connector on the
same (Control and Forward) card.
Tip: The procedure used to download the Regtree file via
the LAN connection may also be used to download other
files to the WMTS, such as new versions of the software.
First, the XmtsConfig.exe tool is used to set a temporary IP address
for the WMTS. This IP address allows the WMTS to appear on the
LAN subnet and communicate with the servers (which are on the same
network). The serial port connection is used to set the temporary IP
address and the LAN connection is used to perform the actual
download (via the temporary IP address previously set using the serial
port connection). After the modified version of Regtree (containing the
PERMANENT IP address of the WMTS) is downloaded and the WMTS
is restarted, the WMTS will be accessible via its PERMANENT IP
address.
Next, we will be modifying regtree.txt to contain the permanent WMTS
IP address, then compiling regtree.txt into regtree.rtr and downloading
it. The download is made by specifying regtree.rtr in the “Version File”
field of the XmtsConfig.exe tool and making sure that regtree.rtr (the
compiled version of regtree.txt) is copied into the TFTP file transfer
folder.
1. Locate the file “regtree.txt” and open it using a standard text editor such
as Notepad (do not use the XmtsConfigFileEditor for this as it does not
allow editing of the necessary entries). There may be several versions of
the Regtree file available (e.g., “regtree_data.txt”, “regtree_t1.txt”, etc.)
so ask your system engineer which one to use, then copy and rename it
to “regtree.txt” since that is the file which SETIP.bat expects as its input
file. Scroll down (or use the “Find” function from the menu) to the entry
CmtsIPAddress” which is shown as 10.10.10.210 in this example. The
default network address for Vyyo equipment is 10.10.10.xxx. Your
system engineer should be able to provide the following information
required to configure the WMTS: