User Manual

Vytek PTX-150
Doc Ref : 7M393-1 Version C1 Page : 15
VYTEK - 2000
so that you can select different protocol (POCSAG or FLEX) just by changing
the input level of Pin1 of DB37.
IV. Click ”M
odem” button to configure dial-out parameters and PMD board.
V. Click ”A
larms” button to set alarm limits for RF power, High VSWR,
Temperature, Voltage and High Current.
VI. Click ”Re
ad” or ” Update” button to Read or Update Transmitter Parameter
Settings.
VII. Click ” D
iagnostics” button to Diagnose the transmitter with real-time
parameters (Forward Power, VSWR, Temperature, Power Voltage, PA Current
and PA driver power) monitoring.
VIII. Click ”Dial R
emote” button to dial remote transmitter with an internal dialer.
Before dialing, please be sure to set the dial MODEM parameters using the
following AT commands: ATS0=1, AT&D0, AT&K0, AT&W0. Then, select item
”M
odem Setup” or ”Dialer Setup” from ”Local Setup” menu to setup local dial
MODEM and dialer.
IX. Click ”L
oad” or ”Save” button to Load/Save the current transmitter settings
from/to a local file.
X. Click ”T
erminal” button to access the terminal program.