5. TROUBLE SHOOTING GUIDE
PROBLEM
The transmitter has a comprehensive test program which initiates on first application
of power. It is important to understand the start up sequence to determine a likely fault
scenario. Table 5.0.1 lists possible symptoms, and solutions to those symptoms.
SYMPTOM POSSIBLE PROBLEM
Dial Modem connected but the system does
not indicate a connection
Power to dial modem is off.
Cable is installed incorrectly
Dial Modem has not been set up as Hayes compatible
9600,8,N,1
No LEDs light up or no tone heard
Mains power is off
Fuse has blown on input connector
Faulty power supply
No RF output power
The SONIK PTX-150 transmitter will turn off the RF
output if any potentially fatal faults develop in the unit.
Fault can be caused by the LIU selecting a channel that is
not configured in software.
If the fault LED is ON you must find out what fault is
causing the problem through the diagnostic software and
repair, or notify the Supplier
Table 5.0.1 - Trouble Shooting
6. USING THE RDK REMOTE TX DIAGNOSTIC PROGRAM
This program is used to monitor all of the transmitter functions in a real-time mode.
To initialize, have a functional transmitter working then select the RDK Remote