User Manual
Table Of Contents
- FOREWORD
- GENERAL OVERVIEW
- SPECIFICATIONS
- ELECTRICAL REQUIREMENTS
- SITE PLANNING
- INSTALLATION
- OPERATION
- POWERING UP THE SYSTEM
- CONNECTING A TERMINAL
- Bootloader
- *************************
- G2BT BOOTLOADER
- Version 2F49405
- *************************
- Current MAC address = 00:01:02:03:04:05
- Current IP address = 11.31.3.4
- Current subnet = 255.255.255.128
- Current gateway = 11.31.3.126
- Current TFTP Server = 10.0.0.1
- Current Download File = g2bt.pkg
- ***You've got 5 seconds to escape normal boot process by entering any key...
- Loading application...
- Application
- QUICK-START CONFIGURATION
- SUBSYSTEMS
- USER INTERFACES
- SW DOWNLOAD PROCESS
- POWER CONTROL
- COMMAND LINE USER INTERFACE
- ALARMS AND MANAGEMENT
- FACTORY DEFAULT VALUES
Sonik G2BT Base Transmitter User Manual
March 14, 2002 65 7M487C4
stnCutback1dB This alarm triggers when the
station has been cutback 1dB
due to a problem other than
power amplifier or
temperature.
Major This alarm clears when the
station is no longer cutback
1dB.
stnCutback3dB This alarm triggers when the
station has been cutback 3dB
due to a problem other than
power amplifier or
temperature.
Major This alarm clears when the
station is no longer cutback
3dB.
stnShutdown This alarm triggers when the
station has been shutdown due
to a problem other than power
amplifier or temperature.
Critic
al
This alarm clears when the
station is no longer shutdown.
SW Download
cutoverFail This alarm triggers when a
failure occurs while switching
to new software version.
Major This alarm is not cleared
internally by the system.
downloadFail This alarm triggers when a
failure occurs during software
download.
Major This alarm is not cleared
internally by the system.
Network
admin This alarm triggers when the
user ADMIN logs on to the
system.
Info This alarm clears when the
ADMIN logs off.
admin2 This alarm triggers when the
user ADMIN is logged on to
the system and a second
session attempts to log on as
ADMIN.
Info This alarm is not cleared
internally by the system.
badLogon This alarm triggers when an
invalid logon attempt is made.
Info This alarm is not cleared
internally by the system.
lanErr This alarm triggers when
transmission or reception
errors are detected on the
Ethernet LAN device.
Major This alarm clears when
successful operation is restored
on the LAN interface and no
further errors are detected.
sessionTimeout This alarm triggers when a
user session has no activity for
longer than the
sessionIdleTimeout threshold.
Info
This alarm is not cleared
internally by the system.
telnet This alarm triggers when a
Telnet user session is
activated.
Info This alarm clears when no
Telnet user sessions are active.
userSessionsExce
eded
This alarm triggers a user
session is intiated that causes
the number of active user
sessions to exceed the
userSession threshold.
Info This alarm clears when the
number of active user sessions
falls below the userSessions
threshold.