User Manual
Table Of Contents
- FOREWORD
- GENERAL OVERVIEW
- SPECIFICATIONS
- ELECTRICAL REQUIREMENTS
- SITE PLANNING
- INSTALLATION
- OPERATION
- POWERING UP THE SYSTEM
- CONNECTING A TERMINAL
- Bootloader
- *************************
- G2BT BOOTLOADER
- Version 2F49405
- *************************
- Current MAC address = 00:01:02:03:04:05
- Current IP address = 11.31.3.4
- Current subnet = 255.255.255.128
- Current gateway = 11.31.3.126
- Current TFTP Server = 10.0.0.1
- Current Download File = g2bt.pkg
- ***You've got 5 seconds to escape normal boot process by entering any key...
- Loading application...
- Application
- QUICK-START CONFIGURATION
- SUBSYSTEMS
- USER INTERFACES
- SW DOWNLOAD PROCESS
- POWER CONTROL
- COMMAND LINE USER INTERFACE
- ALARMS AND MANAGEMENT
- FACTORY DEFAULT VALUES
Sonik G2BT Base Transmitter User Manual
March 14, 2002 64 7M487C4
Distribution
mdpInputTimeou
t
This alarm triggers when no
MDP packets are received
within the MDP timeout
threshold.
Critic
al
This alarm clears when MDP
packets are received.
mdpPktsLostFail This alarm triggers when the
number of MDP packets that
have not been received
exceeds the MDP lost packet
threshold.
Major This alarm is not cleared
internally by the system.
noMDPSatRx This alarm triggers when no
MDP packets are received
from the Satellite Rx within
the noMDPSatRx timeout
threshold.
Minor This alarm is not cleared
internally by the system.
noMDPLan This alarm triggers when no
MDP packets are received
from the LAN within the
noMDPLan timeout threshold.
Minor This alarm is not cleared
internally by the system.
mdpPktCRCFail This alarm triggers when the
number of MDP packet CRC
failure rises above the MDP
packet CRC failure threshold.
Major This alarm is not cleared
internally by the system.
mdpPktBuffFull This alarm triggers when there
is not enough memory to
buffer incoming MDP packets.
Major This alarm is not cleared
internally by the system.
mdpProtocolFail This alarm triggers when an
MDP packet contains data that
does not conform to the MDP
Specification.
Minor This alarm clears when an
MDP packet is received that
contains data that conforms to
the MDP Specification.
satRxCRCFail This alarm triggers when the
Satellite Receiver subsystem
indicates it has received data
with a CRC error.
Minor This alarm clears when the
Satellite Receiver has received
good data.
satRxFail This alarm triggers when the
Satellite Receiver indicates a
failure, or when the CPU
cannot communicate normally
with it.
Major This alarms clears when the
Satellite Receiver does not
indicate an error and the CPU
can communicate normally
with it.
Transmission
dekeyTimeout This alarm triggers when the
station dekey time exceeds the
the dekey timeout threshold.
Critic
al
This alarm clears when the
station is keyed.
inLocalMode This alarm triggers when the
station is in local test mode.
Info This alarm clears when the
station is in remote mode.
pagingDisabled This alarm triggers when the
station has paging disabled.
Critic
al
This alarm clears when the
station has paging enabled.