- Bootloader
- *************************
- G2BT BOOTLOADER
- Version 2F49405
- *************************
- Current MAC address = 00:01:02:03:04:05
- Current IP address = 11.31.3.4
- Current subnet = 255.255.255.128
- Current gateway = 11.31.3.126
- Current TFTP Server = 10.0.0.1
- Current Download File = g2bt.pkg
- ***You've got 5 seconds to escape normal boot process by entering any key...
- Loading application...
- Application
- QUICK-START CONFIGURATION
- SUBSYSTEMS
- USER INTERFACES
- SW DOWNLOAD PROCESS
- POWER CONTROL
- COMMAND LINE USER INTERFACE
- ALARMS AND MANAGEMENT
- FACTORY DEFAULT VALUES
Sonik G2BT Base Transmitter User Manual
March 14, 2002 58 7M487C4
Set or display the station power output setting in Watts (this is the desired power setting,
not the measured output setting as indicated by command TRAN PWROutput).
Oper1
TRANsmission R25colorcode
[ 0…127 ]
Set or display the color code index for ReFLEX25 sync transmission. This value is an
index that gets translated into a Color Code string. Refer to the ReFLEX25 protocol
document for specific information.
Oper1
TRANsmission SUbchan Config
[ 1…4 ]
MOde
[ OFF | ON ]
Set or display the mode for the specified subchannel. A value of
OFF
indicates that no
data should be transmitted for this subchannel, a value of
ON
indicates data should be
transmitted for this subchannel.
Oper1
TRANsmission SUbchan Config
[ 1…4 ]
Frequency
[ -20000… 20000 ]
Set or display the offset frequency for the specified subchannel in Hz.
TRAN
smission SUbchan Config
[ 1…4 ]
Deviation
[ 0… 2400 ]
Set or display the deviation for the specified subchannel in Hz.
Oper1
TRANsmission SUbchan Empty
[ None | Sync | Idle | Ignore ]
Set or display the station transmission mode when a subchannel is received with a block
size of 0. A value of
NONE
indicates that the entire frame is not keyed for any
subchannels. A value of
SYNC
means that only the sync field will be transmitted on the
subchannel(s) that is of size 0. A value of
IDLE
means that sync and idle data pattern
will be transmitted on the subchannel(s) that is of size 0. A value of
IGNORE
indicates
that received subchannels are transmitted normally and nothing is transmitted on the
subchannel(s) that is of size 0.
TRAN
smission TESTStatus
Display the station transmission test status. A value of
ON
indicates that we are currently
testing. A value of
OFF
indicates we are not testing. Refer to the
CA
libration
S
ubchantest
command for activating/deactivating the actual tests.
Oper1
TRANsmission TESTTimout
[ 1…65536 ]
Set or display the test mode (local or remote) timeout value in minutes. This value
indicates the amount of time in minutes the transmitter will stay in test mode while no
test patterns are being transmitted.
Oper1
TRANsmission TXMode
[ NORMAL | LOCAL | REMOTE ]
Set or display the station transmission mode. A value of
NORMAL
indicates we are
transmitting normally, a value of
LOCAL
indicates that we are in test mode triggered by
a front panel console session, a value of
REMOTE
indicates we are in test mode
triggered by a Telnet session.
13.2.23 V
ERSION
…
The following are the commands to display various executing software versions.
V
ersion Boot
Display the bootstrap loader software version.
V
ersion Package