User Manual
Table Of Contents
- FOREWORD
- GENERAL OVERVIEW
- SPECIFICATIONS
- ELECTRICAL REQUIREMENTS
- SITE PLANNING
- INSTALLATION
- OPERATION
- POWERING UP THE SYSTEM
- CONNECTING A TERMINAL
- Bootloader
- *************************
- G2BT BOOTLOADER
- Version 2F49405
- *************************
- Current MAC address = 00:01:02:03:04:05
- Current IP address = 11.31.3.4
- Current subnet = 255.255.255.128
- Current gateway = 11.31.3.126
- Current TFTP Server = 10.0.0.1
- Current Download File = g2bt.pkg
- ***You've got 5 seconds to escape normal boot process by entering any key...
- Loading application...
- Application
- QUICK-START CONFIGURATION
- SUBSYSTEMS
- USER INTERFACES
- SW DOWNLOAD PROCESS
- POWER CONTROL
- COMMAND LINE USER INTERFACE
- ALARMS AND MANAGEMENT
- FACTORY DEFAULT VALUES
Sonik G2BT Base Transmitter User Manual
March 14, 2002 57 7M487C4
TRAC
e
GPS
[ YES | NO ]
Set or display the state of GPS diagnostics messages.
TRAC
e
Mdp
Hdlc
[ YES | NO ]
Set or display the state of MDP via HDLC diagnostics messages.
TRAC
e
Mdp
Tcp
[ YES | NO ]
Set or display the state of MDP via TCP diagnostics messages.
TRAC
e
Mdp
Udp
[ YES | NO ]
Set or display the state of MDP via UDP diagnostics messages.
13.2.22 TRAN
SMISSION
…
The following are the commands relating to station transmission settings.
TRAN
smission Frequency
[929.0000..941.0000 ]
Set or display the station center frequency in MHz.
Oper1, Oper2
TRANsmission INcompleteframe
[ None | ALL ]
Set or display the station transmission mode when a frame has not received or not
received accurate subchannel information. A value of
NONE
indicates that an incomplete
frame is not keyed for any subchannels. A value of
ALL
indicates that
good
received
subchannels are transmitted normally and nothing is transmitted on the subchannel(s) that
is bad or missing.
Oper1
TRANsmission Launchdelay
[ 0…1000 ]
Set or display the station paging frame launch delay in microseconds.
Oper1
TRANsmission Offset
[ -500…500 ]
Set or display the station transmitter subchannel frequency offset in Hz.
Oper1
TRANsmission PAgingmode
[ OFF | ON ]
Set or display the station paging mode status. A value of
OFF
indicates that paging
transmission is disabled, a value of
ON
indicates paging transmission is enabled.
Oper1, Oper2
TRANsmission PWRControlmode
[ OFF | ON ]
Set or display the station power control mode status. A value of
OFF
indicates that power
control is disabled, a value of
ON
indicates power control is enabled. If set to
OFF
the
station output power will remain at or near it’s last value prior to disabling power control.
Power control should only be disabled for maintenance, since cutbacks will not take
effect.
TRANsmission PWROutput
Display the instantaneous station power output in Watts.
TRAN
smission PWRReflected
Display the instantaneous station reflected power in Watts.
Oper1, Oper2
TRANsmission PWRSetting
[ 0…400 ]