User Manual

Table Of Contents
Sonik G2BT Base Transmitter User Manual
March 14, 2002 55 7M487C4
Display the cumulative frame loss per specified frame. Frame loss is defined by frame
data that was not received, was received with data error, was not received in completion,
or was received too late to be launched. The return value will be a count between 0 and
255.
ST
atistics Subchanloading
[ 1…4 ] [ 0…23 ]
Display the specified subchannel loading as a percentage of maximum data (2703360
bytes per hour) for the specified hour.
ST
atistics Cpu
[ cpuNow | cpuMin | cpuMax | cpuAvg ]
Display the percentage of CPU utilization. The
cpuNow
value is updated on 10 second
intervals. The
cpuMin
,
cpuMax
, and
cpuAvg
values are computed from a sample
period of one hour. A value of zero would imply the processor was idle. A value of 100
would imply the processor was fully loaded.
ST
atistics Temp
[ tempNow | tempMin | tempMax | tempAvg ]
Display the internal temperature of the transmitter in degrees centigrade. The now value
is updated on 10 second intervals. The min, max, and avg values are computed from a
sample period of one hour.
Oper1 Oper2
STatistics MDPPKTSRecvd
[ 0…4294967295 ]
Set or displays the total number of MDP packets successfully received since this value
was last set to 0. This number will rollover to 0 when its maximum is exceeded.
Oper1 Oper2
STatistics MDPPKTSLost
[ 0…4294967295 ]
Set or displays the total number of MDP packets not received or received with error since
this value was last set to 0. This number will rollover to 0 when its maximum is
exceeded.
Oper1 Oper2
STatistics TRansmittedFrames
[ 0…4294967295 ]
Set or displays the total number of frames transmitted since this value was last set to 0.
This number will rollover to 0 when its maximum is exceeded.
13.2.20 TH
RESHOLD
The following are the commands relating to alarm threshold settings.
Oper1
THreshold MDPTimeout
[ 1…256 ]
Set or display the MDP timeout alarm threshold in seconds. When no MDP packets are
received within this timeout period, the
mdpInputTimeout
alarm will trigger. The
mdpInputTimeout
alarm will clear when MDP packets are received.
Oper1
THreshold MDPCRC
[ 0…32767 ]
Set or display the MDP CRC alarm threshold in number of packets. When the number of
MDP packets with CRC failures exceeds this value, the
mdpPktCRCFail
alarm will
trigger.
Oper1
THreshold MDPLostPkts
[ 0…32767 ]
Set or display the lost MDP packets alarm threshold in number of packets. When the
number of MDP packets that have been lost (not received) exceeds this value, the
mdpPktsLostFail
alarm will trigger.