User Manual
Table Of Contents
- FOREWORD
- GENERAL OVERVIEW
- SPECIFICATIONS
- ELECTRICAL REQUIREMENTS
- SITE PLANNING
- INSTALLATION
- OPERATION
- POWERING UP THE SYSTEM
- CONNECTING A TERMINAL
- Bootloader
- *************************
- G2BT BOOTLOADER
- Version 2F49405
- *************************
- Current MAC address = 00:01:02:03:04:05
- Current IP address = 11.31.3.4
- Current subnet = 255.255.255.128
- Current gateway = 11.31.3.126
- Current TFTP Server = 10.0.0.1
- Current Download File = g2bt.pkg
- ***You've got 5 seconds to escape normal boot process by entering any key...
- Loading application...
- Application
- QUICK-START CONFIGURATION
- SUBSYSTEMS
- USER INTERFACES
- SW DOWNLOAD PROCESS
- POWER CONTROL
- COMMAND LINE USER INTERFACE
- ALARMS AND MANAGEMENT
- FACTORY DEFAULT VALUES
Sonik G2BT Base Transmitter User Manual
March 14, 2002 45 7M487C4
Set or display the forward channel block count used for calibration and test for the
specified subchannel.
Oper1
CAlibration Testmode
[ START | STOP ]
Set or display the calibration and test mode status. NOTE: The set command will only
take effect if the transmitter has been set in local or remote transmission mode. Refer to
command TRANS
mission TXMode described below.
13.2.3 CL
OCK
...
The following are the commands relating to the station console port settings.
Oper1 Oper2
CLock Date
[ YYYY/MM/DD ]
Display the current system clock date as “YYYY/MM/DD”. The system clock is read at
startup from the on board battery backed up RTC. The RTC and system date/time are
updated when:
•
The operator manually changes the date or time.
•
When GPS data is received indicating valid date/time data that is more than 1 second
different than the current system date/time.
Oper1 Oper2
CLock Time
[ HH:MM:SS ]
Display the current system clock time of day as “HH:MM:SS”. “. The system clock is
read at startup from the on board battery backed up Real-Time-Clock (RTC). The RTC
and system date/time are updated when-
•
The operator manually changes the date or time.
•
When GPS data is received indicating valid date/time data that is more than 1 second
different than the current system date/time.
CLock Uptime
Display the time the system has been running since the last reboot as “DAYS
HH:MM:SS”. It is initialized to zero at startup and continually increments.
CL
ock Operation
Display the time the system has been operational as “DAYS HH:MM:SS”.
CL
ock Reflex Cycle
Display the current ReFLEX cycle number.
CL
ock Reflex Frame
Display the current ReFLEX frame number.
CL
ock Reflex State
Display the current ReFLEX frame state. The returned value will be
MISSING
,
RECEIVED
(MDP packet received) or
LAUNCHED
(frame sent to DSP)
.
13.2.4 CONS
OLE
...
The following are the commands relating to the station console port settings.
Oper1 Oper2
COnsole Timeout
[ 0...4294967295 ]