User Manual

Table Of Contents
Sonik G2BT Base Transmitter User Manual
March 14, 2002 44 7M487C4
Oper1 Oper2
Alarm
[alarmName]
COnsole Enable
[ YES | NO ]
Set or display whether to print a message on the console when this alarm status
changes.
Oper1 Oper2
Alarm
[alarmName]
COnsole Interval
[ 0...4294967295 ]
Set or display how often, in seconds, to redisplay a console message while the alarm
status is SET. Setting this value to zero disables repeating of the alarm message. Setting
this value to 60, for example, will cause a console message to be printed every 60
seconds informing the operator of the alarm until it’s status changes to CLEAR. If
console messages are not enabled this setting has no effect.
Oper1
Alarm
[alarmName]
Trapmsg Enable
[ YES | NO ]
Set or display whether to send SNMP trap message when this alarm status changes. If this
value is set to
YES
an SNMP trap message will be sent to all defined SNMP destinations
(see SNMP [1..5] command). The THRESHOLD TRAPLEVEL and ALARM
alarmName SEVERITY settings also controls transmission of SNMP trap messages.
Oper1
Alarm
[alarmName]
Trapmsg Interval
[ 0…60
]
Set or display how often, in seconds, to retransmit an SNMP trap message while the
alarm status is SET. Setting this value to zero disables repeating SNMP trap messages.
Setting this value to 60, for example, will cause an SNMP trap message to be transmitted
every 60 seconds until it’s status changes to CLEAR. If SNMP trap messages are not
enabled this setting has no effect. The THRESHOLD TRAPLEVEL and ALARM
alarmName SEVERITY settings also controls transmission of SNMP trap messages.
Oper1 Oper2
Alarm
[alarmName]
Log Set
[ YES | NO ]
Set or display whether an entry will be written to the alarm log when this alarm status
transitions from CLEAR to SET. If the alarm is not enabled, or the severity is set to
OFF
,
or if Log is set to
NO
, no log entry will be generated.
Oper1 Oper2
Alarm
[alarmName]
Log Clear
[ YES | NO ]
Set or display whether an entry will be written to the alarm log when this alarm status
transitions from SET to CLEAR. If the alarm is not enabled, or the severity is set to
OFF
,
or the Log Clear is set to
NO
, no log entry will be generated.
13.2.2 CA
LIBRATION
...
The following are the commands relating to station calibration.
Oper1
CAlibration Subchan
[ 1…4 ]
Pattern
[ Disable | SymA | SymB | SymC | SymD |
BigComma | LittleComma | Staircase | PseudoRandom | ReFLEX50 |
Magellan1/4R25 | Magellan1/2R25 | Magellan3/4R25 | Carrier ]
Set or display the pattern used for calibration and test for the specified subchannel
Oper1
CAlibration Framerate
[ 0…128 ]
Set or display the frame rate used for calibration and test. Note that a frame rate of 0
implies a single frame, 1 implies every frame, 2 implies every other frame, 3 implies
every 3
rd
frame, …
Oper1
CAlibration Subchan
[ 1…4 ]
FWdblocks
[ 0…11 ]