March 14, 2002 23 7M487C4
8.3.2.4 ReFLEX25 Color Code Index
TRAN R25colorcode x
8.3.3 N
ETWORK CONFIGURATION
8.3.3.1 IP Address (this is an address in IP notation)
Net Lan Ip x.x.x.x
8.3.3.2 Subnet (this is an address in IP notation)
Net Lan Subnet x.x.x.x
8.3.3.3 Gateway (this is an address in IP notation)
Net Lan Gateway x.x.x.x
8.3.4 I
MPORTANT
A
LARM
T
HRESHOLDS
(
IF DEFAULT OF
20
MINUTES IS NOT DESIRED
)
Alarm thresholds are set in the factory to reasonable defaults.
8.3.4.1 Dekey alarm (timeout in minutes)
THresh Dekey xx
8.3.4.2 Freerun timeout (timeout in minutes)
THresh Freerun xx
8.3.5 C
LEAR
A
LARMS
& A
LARM
L
OGS
To ensure that alarms and the alarm log start from a known state, it is advisable to clear all alarms
and the alarm log.
8.3.5.1 Clearing Alarms
Alarm All STATus Clear
8.3.5.2 Clearing Alarm Log
Log Clear
To save these new configuration settings in non-volatile memory, perform the following
command:
Flash Save