Sonik G2BT Base Transmitter User Manual 2nd Generation Base Transmitter (G2BT) User Manual March 14, 2002 1 7M487C4
Sonik G2BT Base Transmitter User Manual Vytek Wireless, Inc.
Sonik G2BT Base Transmitter User Manual Table of Contents 1 Foreword ....................................................................................................................................... 6 1.1 General Information .................................................................................................. 6 1.2 Computer Software Copyrights................................................................................. 6 1.3 Warnings! ...............................................
Sonik G2BT Base Transmitter User Manual 7.2 Connecting a terminal ............................................................................................. 19 7.2.1 Bootloader ....................................................................................................... 20 7.2.2 Application ...................................................................................................... 21 7.3 Quick-Start Configuration.....................................................................
Sonik G2BT Base Transmitter User Manual 12.2.5 Cutover... ......................................................................................................... 46 12.2.6 Distribution...................................................................................................... 46 12.2.7 Download… .................................................................................................... 47 12.2.8 EXCiter....................................................................................
Sonik G2BT Base Transmitter User Manual 1 FOREWORD 11..11 G GE EN NE ER RA ALL IIN NFFO OR RM MA ATTIIO ON N The information in this manual is preliminary to the production release of the G2BT tranmistter. It is to be used to guide the user in the operation of the equipment, but has not been reviewed for accuracy. No responsibility is assumed for inaccuracies. Vytek Wireless reserves the right to make changes to any product discussed hearin.
Sonik G2BT Base Transmitter User Manual copyrights to the software or firmware in this product are owned by Vytek Wireless, Inc. Vytek reserves all rights not expressly granted to the purchaser of this product.
Sonik G2BT Base Transmitter User Manual 11..33 W WA AR RN NIIN NG GS S!! WARNING ! This device has not yet been approved by the FCC and may not be sold or marketed until such approval is obtained. Changes or modifications to this device that are not expressly approved by Vytek Wireless are prohibited and could void the user’s warranty and possibly his authority to operate this product.
Sonik G2BT Base Transmitter User Manual 2 GENERAL OVERVIEW 22..11 G G22B BTT P PA AG GIIN NG G TTR RA AN NS SM MIITTTTE ER RO OV VE ER RV VIIE EW W The Sonik Second Generation Base Transmitter (G2BT) is a ReFlextm paging transmitter for the 900 MHz frequency band. It is a multi-carrier design, based on the original Motorola Base Transmitter (BT). It Features: FEATURES • • • • Multi-carrier linear transmitter with 1-4 simultaneous, independent carriers.
Sonik G2BT Base Transmitter User Manual If there is an internal AC Uninterruptable Power Supply in the station, there still may be AC power applied to some sub-systems when both of the circuit-breakers on the front of the unit are turned off! The control-equipment chassis has its own battery back-up and will continue to run, even after the AC power is switched off with the front-panel circuit breakers. You must switch it off with the On/OFF switch on the front of the CE Power Supply. 2.2.
Sonik G2BT Base Transmitter User Manual GREEN ● AMBER ● RED ● Power LED Online Warming up or unit is off-line. It is also amber when the network paging feed is disabled. Diagnostics mode.
Sonik G2BT Base Transmitter User Manual 3 SPECIFICATIONS 33..11 R RFF S SP PE EC CIIFFIIC CA ATTO OIIN NS S Function Specification Operating Frequency Range Modulation Modes 929.00 – 941.00 MHz Per ReFLEX 2.7 and ReFlex 50 specs: 4 level FSK, 3200 & 6400 bps 2 level FSK, 1600 & 3200 bps Programmable, 1μS to 1 mS +/- 2.5 ppm 1 μS 1 μS <= 10 mS Rated power before first sync symbol <= -13 dBm within 2.5 mS 10 KHz or 12.
Sonik G2BT Base Transmitter User Manual Satellite Receiver Connector Ethernet LAN Connector Weight Front Panel Console Connector Connector Locations Connector Finish Intrusion Alarms “F” Type Female RJ-45 [10baseT] < 500 pounds DB-9 Female Accessible, with clearance for wrenches Resistant to corrosion, oxidation Front and rear doors 33..
Sonik G2BT Base Transmitter User Manual 4 ELECTRICAL REQUIREMENTS All electrical wiring for the site must meet the requirements of the National Electrical Code (NEC) and all applicable local codes. All conductors must be made of copper. The G2BT paging Transmitter is supplied with a NEMA L14-30P plug. 240V/12-V is supplied from a center-tapped transformer. The two 120V circuits are 180 degrees out of phase, therefore 240VAC is available betweent he phases.
Sonik G2BT Base Transmitter User Manual 5 SITE PLANNING Vytek recommends the following considerations when selecting a site to locate the transmitter at: 1. A minimum floor-space of 20 square feet to allow acess to the front and rear of the cabinet. 2. Floor loading capable of supporting the weight of the cabinet and personel operating the cabinet. 3. A minimum ceiling height of 7 feet. 4.
Sonik G2BT Base Transmitter User Manual 6 INSTALLATION 66..11 C CA AB BIIN NE ETT G GR RO OU UN ND DIIN NG G Safety and operation depends on proper grounding of the equipment. The main cabinet ground is on the top of the cabinet, as shown in the following diagram. The main cabinet ground connects to the cabinet rail, and each chassis installed in the cabinet has an independent ground.
Sonik G2BT Base Transmitter User Manual 6.2.2 TRANSMITTER RF OUTPUT This Transmitter is designed to operate with a fixed mounted outdoor antenna only. The placement should be such that personnel are prevented from inadvertently being within six meters of the antenna.
Sonik G2BT Base Transmitter User Manual 7 7.1.1 SATELLITE RECEIVER 77..22 N NE ETTW WO OR RK KC CO ON NN NE EC CTTIIO ON NS S If the frame-relay interface is installed on the unit, there is a line filer-box attached to the top of the cabinet. The connection to the network is via screw-down terminals on this filter box. You can determine the proper connections to the network by following the wire colors on the transmitter side of the filter-box.
Sonik G2BT Base Transmitter User Manual 8 OPERATION 88..11 P PO OW WE ER RIIN NG GU UP P TTH HE ES SY YS STTE EM M Upon applying power to the G2BT, the software will bootstrap itself before transmission or calibration is possible. 88..22 C CO ON NN NE EC CTTIIN NG GA A TTE ER RM MIIN NA ALL To monitor the boot-up process, connect a computer running HyperTerminal (or any similar terminal emulation program) to the front Console port of the G2BT.
Sonik G2BT Base Transmitter User Manual HyperTerminal Settings 8.2.1 BOOTLOADER The bootloader code is the first software executed in the bootstrap process. Its function is to initialize and verify basic hardware functionality, then load and pass execution on the application software. Loading the final application software can be circumvented for diagnostic purposes, however under normal circumstances the bootloader should be allowed to run without any user intervention.
Sonik G2BT Base Transmitter User Manual ************************* G2BT BOOTLOADER Version 2F49405 ************************* Current MAC address = 00:01:02:03:04:05 Current IP address = 11.31.3.4 Current subnet = 255.255.255.128 Current gateway = 11.31.3.126 Current TFTP Server = 10.0.0.1 Current Download File = g2bt.pkg ***You've got 5 seconds to escape normal boot process by entering any key... Loading application... The Power LED on the front panel will light orange. 8.2.
Sonik G2BT Base Transmitter User Manual 88..33 Q QU UIIC CK K--S STTA AR RTT C CO ON NFFIIG GU UR RA ATTIIO ON N All user configuration settings will have factory defaults set prior to shipment. However there are several settings that are unique to each unit and must be configured in order for the transmitter to function correctly in the field. In order to change configuration settings, a “user session” must be created by logging into the command line interface.
Sonik G2BT Base Transmitter User Manual 8.3.2.4 ReFLEX25 Color Code Index TRAN R25colorcode x 8.3.3 NETWORK CONFIGURATION 8.3.3.1 IP Address (this is an address in IP notation) Net Lan Ip x.x.x.x 8.3.3.2 Subnet (this is an address in IP notation) Net Lan Subnet x.x.x.x 8.3.3.3 Gateway (this is an address in IP notation) Net Lan Gateway x.x.x.x 8.3.4 IMPORTANT ALARM THRESHOLDS (IF DEFAULT OF 20 MINUTES IS NOT DESIRED) Alarm thresholds are set in the factory to reasonable defaults. 8.3.4.
Sonik G2BT Base Transmitter User Manual 9 SUBSYSTEMS 99..11 G G22B BTT C CO ON NTTR RO OLL C CH HA AS SS SIIS S The G2BT Control Equipment Chassis houses the “brains” of the G2BT. All functionality is supported by the modules in this Chassis, with the exception of high-power RF generation. Its modular construction allows for easy field service. Most of the individual modules have backward compatibility with existing SkyTel BTs.
Sonik G2BT Base Transmitter User Manual 9.1.1 CE BACKPLANE The G2BT Control Equipment Backplane has the I/O connections for the CE chassis. The following diagram shows the location of the connectors. J27 J14 J15 J8 J23 J12 J22 J7 J11 J10 J21 J9 J20 J26 J13 J17 G2BT CE Backplane 9.1.1.
Sonik G2BT Base Transmitter User Manual J7 P9 J7 P1 0 J7 P1 1 J7 P1 2 J7 P1 3 J7 P1 4 J7 P1 5 J7 P1 6 J7 P1 7 J7 P1 8 J7 P1 9 J7 P2 0 J7 P2 1 J7 P2 2 J7 P2 3 J7 P2 4 J7 P2 5 J7 P2 6 J7 P2 7 J7 P2 8 J7 P2 9 J7 P3 0 J7 P3 1 Wildcard out 2+ Wildcard in 3 Wildcard out 2+ Wildcard in 3 AsyncCTS + Wildcard in 3 AsyncCT S+ MODEM_CTS A J3-P67, J16-P5, J25-P5 TX OK+ Wildcard out 3+ AsyncDSR + AsyncDS R+ MODEM_DSR A J3-P69, J16-P6, J25-P6 Wildcard in 4 Wildcard in 4 Wildcard in 4 RFC MAINT B R(B) A
Sonik G2BT Base Transmitter User Manual J7 P3 2 J7 P3 3 Wildcard out 5 Wildcard out 5 Wildcard out 5 Wildcard out 6 Wildcard out 6 Wildcard out 6 9.1.1.
Sonik G2BT Base Transmitter User Manual B J16P11 MODEM_SCT EB From Backplane J3-P3, J25-P11 MODEM_SCTEB J16P12 MODEM_TXC B To Backplane J4-P34, J25-P12 MODEM_TXCB J16P13 MODEM_CTS B To Backplane J4-P70, J7-P27, J25-P13 MODEM_CTSB J16P14 MODEM_TXD B From Backplane J3-P12, J7-P14, J25-P14 MODEM_TXDB J16P15 MODEM_TXC A To Backplane J3-P60, J25-P15 MODEM_TXCA J16P16 MODEM_RXD B To Backplane J3-P10, J7-P16, J25-P16 MODEM_RXDB J16P17 MODEM_RXC A To Backplane J3-P18, J25-P17 MODE
Sonik G2BT Base Transmitter User Manual J10P3 GND To Backplane Backplane 9.1.1.6 J11 Aux +14 Vdc Interface (3 Pin Male Snap and Lock Connector) PIN FUNCTION DIRECTION CONNECTS TO J11P1 +14VDC From Backplane J1P16-23 J11P2 GND To Backplane Backplane J11P3 GND To Backplane Backplane 9.1.1.
Sonik G2BT Base Transmitter User Manual J14P1 Not used J14P2 Not used J14P3 Not used J14P4 Not used J14P5 GPS_RX+ From Backplane J5-P5 J14P6 GPS_1PPS+ From Backplane J5-P7 J14P7 GPS_RDY From Backplane J5-P10 J14P8 GND From Backplane J14P9 GND From Backplane J14P10 GND From Backplane J14P11 GND From Backplane J14P12 Not Used J14P13 GPS_RX- From Backplane J5-P6 J14P14 GPS_1PPS- From Backplane J5-P8 J14P15 GPS_MSTR_SEL From Backplane J5-P9 9.1.1.
Sonik G2BT Base Transmitter User Manual 9.1.1.11 J17 Telco Interface (8 Conductor Modular Keyed Socket) PIN FUNCTION DIRECTION CONNECTS TO J24P1 SIG1 Programmable J25P73 J24P2 SIG2 Programmable J25P74 J24P3 SIG3 Programmable J25P75 J24P4 SIG4 Programmable J25P76 J24P5 SIG5 Programmable J25P77 J24P6 SIG6 Programmable J25P78 J24P7 SIG7 Programmable J25P79 J24P8 SIG8 Programmable J25P80 9.1.1.
Sonik G2BT Base Transmitter User Manual J17P15 9.1.1.14 Not used J22 Internal Detector Interface (9 Pin Female D Sub Connector) PIN FUNCTION DIRECTION CONNECTS TO J18P1 VREF1 To Backplane J2RCP8 J18P2 +28 Vdc From Backplane Backplane J18P3 GND To Backplane Backplane J18P4 GND To Backplane Backplane J18P5 VFWD1 To Backplane J2RCP7 J18P6 SHIELD_GND To Backplane Backplane J18P7 Not used J18P8 Not used J18P9 Not used 9.1.1.
Sonik G2BT Base Transmitter User Manual 9.1.1.17 J27 Exciter RF Out (Female SMA) PIN FUNCTION DIRECTIO N CONNECTS TO J22 CTR CON RF_OUT From Backplane To Splitter J22 OTR CON GND To Backplane Backplane 9.1.1.
Sonik G2BT Base Transmitter User Manual 99..22 C CE EP PO OW WE ER RS SU UP PP PLLY Y The control chassis power supply has been designed by Mesa Power Systems. It has its own AC power supply with provision battery-back-up for up to 15 minutes of operation. Internally, it uses an off-the-shelf AC-DC switching power converter. A simple micro-controller monitors the AC supply, battery voltage and current, and battery charging. It communicates this status information to the CPU via the SPI bus.
Sonik G2BT Base Transmitter User Manual 10 USER INTERFACES 1100..11C CO OM MM MA AN ND D LLIIN NE EE ED DIITTO OR R The command line editor accumulates keystrokes from user input into a command line to be passed to a command line interpreter (CLI) then displays the results of the command. The editor interacts with the operator allowing characters in the command to be inserted and deleted before it is submitted to the CLI.
Sonik G2BT Base Transmitter User Manual • Admin all display/set commands • Oper1 all display commands, all set commands except critical system settings • Oper2 all display commands, some set commands • Oper3 all display commands, no set commands March 14, 2002 36 7M487C4
Sonik G2BT Base Transmitter User Manual 11 SW DOWNLOAD PROCESS There are three phases in the software download process: 1. Receive the software download file. 2. Write the software download file into Flash memory. 3. Cutover to the new version of downloaded software. 1111..
Sonik G2BT Base Transmitter User Manual The G2BT contains Flash memory to store two complete images of the software download file (i.e. two complete images of each of the binary images for the SCM software, the DSP software and the FPGA configuration code). One virtual Flash memory bank contains a copy of the currently active software images, the other virtual Flash memory bank contains a copy of a dormant set of binary images.
Sonik G2BT Base Transmitter User Manual 12 POWER CONTROL 1122..11IIN NTTR RO OD DU UC CTTIIO ON N The power control function is designed to control keying and dekeying of the RF transmitter, monitor the functionality and integrity of the exciter, power amplifiers, and the PA power supplies, and operate the control loop that maintains the RF power output at the desired level. 1122..
Sonik G2BT Base Transmitter User Manual The power reporting and control system take into account the number of carriers being transmitted at any one time. The power setting and reporting value is the total station RF output power, in watts. For example, if there are 4 carriers enabled, and the user sets the station power to 400 watts, each carrier will be controlled to 100 watts. When the station is transmitting, it will report 400 watts as being full power.
Sonik G2BT Base Transmitter User Manual Cutback by 1 dB VSWR at 1 PA RF output connector > 3:1 Cutback by 3 dB Station de-keys VSWR at 1 PA RF output connector > 10:1 VSWR at more than 1 PA RF output connector > 10:1 VSWR at antenna connector > 3:1 VSWR at antenna connector > 10:1 Temperature of station exceeds 65˚C Temperature of station exceeds 70˚C Temperature of station exceeds 80˚C One or more PAs issue a temperature warning 1 PA or 1 PSU fails internally in a 400W station More than 1 PA a
Sonik G2BT Base Transmitter User Manual 13 COMMAND LINE USER INTERFACE The command line interface is a password-protected English language command interpreter. The command structure is based on a hierarchy of parameter mnemonics that can be displayed or modified and additional commands that can activate subprograms, which may display reports, such as the “ping” command, or run interactively, such as the “menu” command.
Sonik G2BT Base Transmitter User Manual 1133..22C CO OM MM MA AN ND D LLIIS STT 13.2.1 ALARM... There are a number of alarm events which operate and can be configured independently. Each alarm event alarmName is managed by the following sub-commands. See Section “Alarms and Management” for alarm management and conditions. Oper1 Alarm [alarmName] Enable [ YES | NO ] Set or display whether this alarm is operational.
Sonik G2BT Base Transmitter User Manual Oper1 Oper2 Alarm [alarmName] COnsole Enable [ YES | NO ] Set or display whether to print a message on the console when this alarm status changes. Oper1 Oper2 Alarm [alarmName] COnsole Interval [ 0...4294967295 ] Set or display how often, in seconds, to redisplay a console message while the alarm status is SET. Setting this value to zero disables repeating of the alarm message.
Sonik G2BT Base Transmitter User Manual Set or display the forward channel block count used for calibration and test for the specified subchannel. Oper1 CAlibration Testmode [ START | STOP ] Set or display the calibration and test mode status. NOTE: The set command will only take effect if the transmitter has been set in local or remote transmission mode. Refer to command TRANSmission TXMode described below. 13.2.3 CLOCK... The following are the commands relating to the station console port settings.
Sonik G2BT Base Transmitter User Manual Set or display the console port user interface inactivity timeout period in seconds. Setting this value to zero disables the session inactivity timeout function. Any other setting will abort user sessions after the configured number of seconds expires with no input from the user. Oper1 Oper2 COnsole Baud [ 300 | 600 | 1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200 ] Set or display the baud rate operating on the front panel RS-232 serial console port.
Sonik G2BT Base Transmitter User Manual Set or display the distribution upper hysteresis CRC limit for good HDLC frames received. The parameter is a percentage of good HDLC frames received. Oper1 DIstribution Hdlc NUmcrcframes [ 0…30000 ] Set or display the distribution HDLC frames CRC error measurement. The parameter is the computational interval in frames. Oper1 DIstribution Hdlc NEtzone 1 [ 0…65536 ] Set or display the distribution network zone address 1.
Sonik G2BT Base Transmitter User Manual Oper1 DOwnload Mode [ OFF | NOW | TIMED ] Set or display the remote software download mechanism. A value of OFF indicates software downloads cannot be done remotely. A value of NOW will start a download immediately. A value of TIMED indicates the station will begin making TFTP file requests of the specified filename at the time specified to the specified server IP address. Oper1 DOwnload SErver [ a.b.c.
Sonik G2BT Base Transmitter User Manual Set or display the tranlin training interval in minutes. A value of zero indicates training at every keyup. A value of NOW indicates training will take place at the next available key point (the set numerical value will not be altered). 13.2.9 EXIT This command will end the user session. 13.2.10 FLASH... The following are the commands relating to the firmware contained in flash memory. Oper1 Flash Default Restore the configuration to the factory default settings.
Sonik G2BT Base Transmitter User Manual Displays the latitude reported by position device in radians (degrees, minutes, seconds). Gps LOngitude Displays the longitude reported by position device in radians (degrees, minutes, seconds). Gps SAtellite Tracked Displays the number of tracked satellites. Gps SAtellite Visible Displays the number of visible satellites. Gps SYnc Displays the current state of the timing synchronization status.
Sonik G2BT Base Transmitter User Manual Set or display the transmitter host name. The host name can be up to 16 characters. Oper1 Network Lan Ipaddr [ a.b.c.d ] Set or display the IP address of the Ethernet LAN link in Internet dot notation. Oper1 Network Lan Subnet [ a.b.c.d ] Set or display the IP address subnet mask of the Ethernet LAN interface for this device in Internet dot notation. Network Lan Macaddr Display the Ethernet LAN MAC address.
Sonik G2BT Base Transmitter User Manual Display the number of Power Amplifiers installed in the station transmitter. PA Operational Display the number of Power Amplifiers in the station that are currently operational. PA [ 1…4 ] Attenlevel Display the attenuation level of the specified Power Amplifier. PA [1…4 ] Current Display the DC supply current in Amps of the specified Power Amplifier. Oper1 PA [ 1…4 ] Enable [ YES | NO ] Set or display the state of the specified power amplifier.
Sonik G2BT Base Transmitter User Manual Display the current of the specified power amplifier power supply in Amps. The returned value will be a number between 0 and 50. Oper1 PS [ 1…4 ] Enable [ YES | NO ] Set or display the state of the specified power amplifier power supply. A YES value implies that the power supply is enabled, a NO value implies that the power supply is not enabled. PS [ 1…4 ] Overcurrent Display the overcurrent status of the specified power amplifier power supply.
Sonik G2BT Base Transmitter User Manual 13.2.18 SNMP… The following are the commands relating to the SNMP settings. Oper1 SNmp Getcommunity Set or display the SNMP community name used to validate SNMP get request messages. Changing this value does not take effect until the system is restarted. Oper1 SNmp Setcommunity Set or display the SNMP community name used to validate SNMP set request messages. Changing this value does not take effect until the system is restarted.
Sonik G2BT Base Transmitter User Manual Display the cumulative frame loss per specified frame. Frame loss is defined by frame data that was not received, was received with data error, was not received in completion, or was received too late to be launched. The return value will be a count between 0 and 255. STatistics Subchanloading [ 1…4 ] [ 0…23 ] Display the specified subchannel loading as a percentage of maximum data (2703360 bytes per hour) for the specified hour.
Sonik G2BT Base Transmitter User Manual Oper1 THreshold NOMDPSatrx [ 1…32767 ] Set or display the alarm threshold in minutes of no MDP packets received from the Satellite Receiver.When the number of minutes exceeds this value, the noMDPSatRx alarm will trigger. Oper1 THreshold NOMDPLan [ 1…32767 ] Set or display the alarm threshold in minutes of no MDP packets received from the LAN. When the number of minutes exceeds this value, the noMDPLan alarm will trigger.
Sonik G2BT Base Transmitter User Manual TRACe GPS [ YES | NO ] Set or display the state of GPS diagnostics messages. TRACe Mdp Hdlc [ YES | NO ] Set or display the state of MDP via HDLC diagnostics messages. TRACe Mdp Tcp [ YES | NO ] Set or display the state of MDP via TCP diagnostics messages. TRACe Mdp Udp [ YES | NO ] Set or display the state of MDP via UDP diagnostics messages. 13.2.22 TRANSMISSION… The following are the commands relating to station transmission settings.
Sonik G2BT Base Transmitter User Manual Set or display the station power output setting in Watts (this is the desired power setting, not the measured output setting as indicated by command TRAN PWROutput). Oper1 TRANsmission R25colorcode [ 0…127 ] Set or display the color code index for ReFLEX25 sync transmission. This value is an index that gets translated into a Color Code string. Refer to the ReFLEX25 protocol document for specific information.
Sonik G2BT Base Transmitter User Manual Display the executing software package version. Version Machine Display the machine serial number. 13.2.24 WATCH Below describes the Watch command, which allows the user to define periodic commands. Watch [ 1 … 3600] [COMMAND] Specify a command to run between 1 to 3600 seconds. If no time is specified, the default is 1 second. The command can be any valid command defined above.
Sonik G2BT Base Transmitter User Manual 14 ALARMS AND MANAGEMENT The G2BT includes an SNMP agent allowing remote management and providing the primary alarm notification mechanism to the NOC. Station configuration, status, and statistics can be inspected using the SNMP protocol. Configuration parameters can also be set using SNMP. Current alarm status and station statistics are presented through the SNMP MIB in table form. Unsolicited alarm messages are delivered to the NOC through SNMP trap messages.
Sonik G2BT Base Transmitter User Manual Several parameters for the given alarm will provide control information as to how the alarm instance will be handled subsequence to the status and stats update. These parameters control the overall alarm handling, display to the console session, the sending of alarm event trap messages to a network manager and the logging of the given alarm instance.
Sonik G2BT Base Transmitter User Manual The given alarm is sent to a network manager via a SNMP trap message if TrapMsg enable is “yes” AND the given alarm severity level is greater than or equal to the “Thresholds trapLevel” parameter.
Sonik G2BT Base Transmitter User Manual lostACPwr This alarm triggers when the AC power is lost and the system is running off the battery. Critic al This alarm clears when the AC power is online. g2btFail This alarm triggers when the G2BT fails. Critic al This alarm clears when the G2BT is working properly. parmsNotSaved This alarm triggers when the user ADMIN logs off without saving the system configuration to FLASH memory.
Sonik G2BT Base Transmitter User Manual Distribution mdpInputTimeou t This alarm triggers when no MDP packets are received within the MDP timeout threshold. Critic al This alarm clears when MDP packets are received. mdpPktsLostFail This alarm triggers when the number of MDP packets that have not been received exceeds the MDP lost packet threshold. Major This alarm is not cleared internally by the system.
Sonik G2BT Base Transmitter User Manual stnCutback1dB This alarm triggers when the station has been cutback 1dB due to a problem other than power amplifier or temperature. Major This alarm clears when the station is no longer cutback 1dB. stnCutback3dB This alarm triggers when the station has been cutback 3dB due to a problem other than power amplifier or temperature. Major This alarm clears when the station is no longer cutback 3dB.
Sonik G2BT Base Transmitter User Manual Exciter Subsystem exciterFail This alarm triggers when the exciter fails. Critic al This alarm clears when the exciter is functioning normally. paFail This alarm triggers when a power amplifier is not functioning or reports a failure. Major This alarm clears when all power amplifiers are functioning normally. paOverdrive This alarm triggers when a power amplifier is in an overdrive condition.
Sonik G2BT Base Transmitter User Manual 15 FACTORY DEFAULT VALUES The following values are programmed into the unit, as the factory defaults.
Sonik G2BT Base Transmitter User Manual Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm PwrCntrlFail COnsole Enable = YES PwrCntrlFail COnsole Interval = 60 PwrCntrlFail TrapMsg En
Sonik G2BT Base Transmitter User Manual Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm NoMDPLAN COnsole Enable = YES NoMDPLAN COnsole Interval = 60 NoMDPLAN TrapMsg Enable = YES N
Sonik G2BT Base Transmitter User Manual Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm PagingDisabled Log Clear = YES Cutback1dB SEverity = MAJOR Cutback1dB COnsole Enable = YES C
Sonik G2BT Base Transmitter User Manual Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm Alarm LANError Log Clear = YES SessionTimeout SEverity = INFO SessionTimeout COnsole Enable = YES
Sonik G2BT Base Transmitter User Manual Alarm PSFail TrapMsg Interval = 0 Alarm PSFail Log Set = YES Alarm PSFail Log Clear = YES Alarm PSOverCurrent Enable = NO Alarm PSOverCurrent SEverity = MAJOR Alarm PSOverCurrent COnsole Enable = YES Alarm PSOverCurrent COnsole Interval = 60 Alarm PSOverCurrent TrapMsg Enable = YES Alarm PSOverCurrent TrapMsg Interval = 0 Alarm PSOverCurrent Log Set = YES Alarm PSOverCurrent Log Clear = YES Alarm GPSNoLock SEverity = CRITICAL Alarm GPSNoLock COnsole Enable = YES Alar
Sonik G2BT Base Transmitter User Manual EXCiter DAC = 0x0330 EXCiter tranlin 01 = 0x0E EXCiter tranlin 02 = 0x14 EXCiter tranlin 03 = 0x31 EXCiter tranlin 04 = 0xF1 EXCiter tranlin 05 = 0x18 EXCiter tranlin 06 = 0x27 EXCiter tranlin 07 = 0x3C EXCiter tranlin 08 = 0x38 EXCiter tranlin 09 = 0xBB EXCiter tranlin 0A = 0x51 EXCiter tranlin 0B = 0x7E EXCiter tranlin 0C = 0xA5 EXCiter tranlin 0D = 0x40 EXCiter tranlin 0E = 0x20 EXCiter tranlin 0F = 0xFF EXCiter tranlin 10 = 0x36 EXCiter tranlin 11 = 0x4D EXCiter
Sonik G2BT Base Transmitter User Manual THreshold NOMDPLan = 10 THreshold NOMDPSatrx = 10 THreshold Sessionidletime = 256 THreshold TEMPHigh = 80 THreshold TEMPLow = 5 THreshold TRaplevel = MINOR THreshold Usersessions = 6 TRANsmission Frequency = 940.