Operation RF-Baton! Transmitter Controller Installation and Operation
5-2 6880497G01-B June 1999
Figure 5-1: RF-B! Transmitter Controller (Front View)
Service Terminal Setup
Perform the following steps to connect the service terminal for communications:
1. Connect the service terminal to the RF-B! transmitter controller serial port connector
using an RS-232 cable with a DB-9 connector and a null modem adapter. (See Figure 5-1).
Note: The RF-B! transmitter controller serial port connector is configured as Data Terminal
Equipment (DTE). A null modem adapter must be used for the service terminal to interface
with the serial port connector.
2. Switch on the service terminal.
3. Set the flow control to none.
4. Set the service terminal to the parameters listed below (see Table 5-1).
Table 5-1: Service Terminal Interface Parameters
Description Setting
Baud rate 9600 (Default Value)
Parity rate None
Data bits 8
Stop bits 1
Emulation VT100
Serial Port
RESET
Control On
Control Fail
Disable
Alarm
Distribution OK
GPS Lock
RFB Req
TX OK
RF-Baton!™
Serial Port
705SRH-10
POWER