User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
RF-Baton! Transmitter Controller Installation and Operation Installation
June 1999 6880497G01-B 4-29
19. Clear the Logs.
At the prompt, type:
a 103 <Enter>
The system responds:
RA 103
Note: Two standard alarms are logged upon RF-B! transmitter controller reset. Clearing the alarm
log also clears the front panel ALARM LED.
At the prompt, type:
a 111 <Enter>
The system responds:
RA 111
At the prompt, type:
a 113 <Enter>
The system responds:
RA 113
20. Verify the following LEDs on the RF-B! transmitter controller are lit:
– Control ON (green)
– Distribution OK (green)
– GPS Lock (green)
– RF-B REQ (green)
– TX_OK (green)
The RF-B! transmitter controller operation checkout is complete.