User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Installation
June 1999 6880497G01-B 4-27
13. Verify the RF-B! transmitter controller is sending data to the transmitter over the PnP
connection.
At the prompt, type:
a 192 DRT1 1 <Enter>
The system responds:
RA 192
DRTR1: inc=185 delta=185 mod=0 id=832854C
Note: The presence of the trace is proof. The actual trace content may change according to your
system setup.
14. Disable the PnP data router trace.
At the prompt, type:
a 193 DRT1 1 <Enter>
The system responds:
RA 193
The trace stops.
15. Finally, verify that the RF-B! transmitter controller is keying the transmitter. Verify the PA
Keyed LED (fourth LED from the right) on the RF-O! transmitter is On (see Figure 4-6).
Figure 4-6: RF-O! transmitter Front Panel
RESET
Control On
Control Fail
Disable
Alarm
PA Keyed
Exciter Locked
Full Power
Pwr Ctbck
RF-Orchestra!™
Serial Port
302SRH-13
Power
PA Keyed