User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Installation RF-Baton! Transmitter Controller Installation and Operation
4-26 6880497G01-B June 1999
10. Disable the OPPM trace.
At the prompt, type:
a 193 OPPM 4 <Enter>
The system responds:
RA 193
The trace stops
11. Verify that the RF-B! transmitter controller has enabled paging.
At the prompt, type:
a 192 PCRM 2 <Enter>
The system responds:
RA 192
The trace begins. If using the RF-C! controller to generate input data and paging is
enabled, the following message is displayed:
Paging is Enabled!
Note: When paging is enabled, the RF-B! transmitter controller has recognized that:
a) The TX_OK line is set.
b) The Simulcast Manager is in a simulcast operational state.
c) Paging has not been disabled by the user (using FIPS).
If using the RF-B! transmitter controller generated test messages, the following message
is displayed:
In test mode!
12. Disable the Page Control Receive Manager (PCRM) trace.
At the prompt, type:
a 193 PCRM 2 <Enter>
The system responds:
RA 193
The trace stops.