User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Installation
June 1999 6880497G01-B 4-25
9. If using the RF-C! controller for input message data, verify the RF-C! controller to RF-B!
transmitter controller connection using the Outbound Paging Protocol Manager (OPPM)
trace.
At the prompt, type:
a 192 OPPM 4 <Enter>
Note: This trace has no meaning if using the RF-B! transmitter controller test modes to generate test
message data. If you are using test modes, skip to Step 11.
The system responds:
RA 192
====================================================
PdmData { } = PilotOnly
Time { } = 42 : 22 : 6150000
PdmApdu { } =
rfChannelIndex = 0
subchannel = 2
====================================================
PdmData { } = InflexionSqm
Time { } = 42 : 22 : 6350000
PdmApdu { } =
rfChannelIndex = 0
subchannel = 2
====================================================
PdmData { } = InflexionAdpcm24
Time { } = 42 : 22 : 7250000
PdmApdu { } =
rfChannelIndex = 0
subchannel = 2
SideBandMode = 0 (0 = lower, 1 = upper)
====================================================
Note: The exact output of this trace depends on the input data. The presence of this trace verifies the
RF-C! controller to RF-B! transmitter controller connection