User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Installation RF-Baton! Transmitter Controller Installation and Operation
4-18 6880497G01-B June 1999
RF-B! Transmitter Controller Specific Setup
In addition to the networking parameters set in the preceding procedure, there are also RF-B!
transmitter controller specific parameters that must be set upon installation. A table of the
necessary information is provided below. Record the site specific values in Table 4-6.
1. Start a FIPS session (see Chapter 5, "Operation", paragraph, "Service Terminal").
Note: Keyboard conventions were previously described (see Chapter 1, "Introduction", paragraph,
"Keyboard Conventions".)
2. Set the transmitter color code value.
At the prompt, type:
w 704 [value] <Enter> where value= 0–65535 decimal
3. Set the BCM serial number.
At the prompt, type:
w 155 [identifier number] <Enter> where serial number is 8 alphanumeric characters
4. For paging stations using the FLEX protocol, it is necessary to set the station id.
At the prompt, type:
a 59 [station id] <Enter>
Where station ID is up to 12 alphanumeric characters
The RF-B! transmitter controller site specific parameters are set.
Table 4-6: Site-Specific RF-B! Transmitter Controller Parameter Checklist
Parameter Related FIPS Command Value
Transmitter Color Code Value r or w 704
Baton Control Module (BCM) Identifier Number r or w 155
Station ID a 58
a 59
write
read