User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
RF-Baton! Transmitter Controller Installation and Operation Installation
June 1999 6880497G01-B 4-15
General Operational Setup and First Time Use
The factory installs all software necessary for operating the RF-B! transmitter controller. There
are, however, site specific setups that are necessary before the RF-B! transmitter controller is
ready to perform paging operation. The following sections provide detailed procedures for all
site specific setups.
All setup procedures use a service terminal using the Friendly Integrated Paging
System (FIPS) protocol to interface with the RF-B! transmitter controller. If unfamiliar with
this interface, reference Chapter 5, "Operation", paragraph, "Service Terminal" for a detailed
FIPS tutorial.
The setup procedures are broken down into the following parts:
• Networking
• Transmitter interface, RF-B! setup
• GPS value recording
Networking Setup
This procedure configures the RF-B! transmitter controller site specific networking parameters
for normal operation with an ethernet input. Refer to the site network plan for the information
required to complete this procedure. Record the site specific values of the networking
information in Table 4-5.
If using multicast, refer to Chapter 6, "Maintenance", paragraph, "Assigning an RF-B!
Transmitter Controller to a Multicast Group".
Table 4-5: Site-Specific Network Parameter Checklist
Parameter Related FIPS Command Value
OPP UDP Port r or w 55 See the network site plan.
RF-B! IP Address r or w 705
Subnet Mask r or w 706
Default Gateway Address r or w 708
SNMP Network Manager Address r or w 500, 501,502, 503, 504
TFTP Server IP Address a 301