User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Installation RF-Baton! Transmitter Controller Installation and Operation
4-14 6880497G01-B June 1999
6. Turn on network peripherals (refer to the appropriate vendor manuals).
7. Release the front cover of the RF-Audience! (RF-A!) receiver and place the POWER
switch in the ON (|) position.
Repeat for all co-located receivers.
8. Upon Initial installation, ensure the RF-O! paging station is continuously powered up
and uninterrupted for at least 60 minutes to allow the GPS receiver time to determine the
site location, build the GPS almanac, and lock on to the appropriate satellites.
– The Exciter Lock LED on the RF-O! transmitter lights within 15 minutes.
– The GPS LOCK LED on the RF-B! transmitter controller lights within 25 minutes.
When the Exciter Lock LED on the RF-O! transmitter and the GPS Lock LED on the RF-B!
transmitter controller light, the station is ready for paging. Subsequent resets of the RF-B!
transmitter controller do not require as long to initialize if the station has not been moved.
Table 4-4: Normal RF-B! Transmitter Controller LED Conditions
LED Function
Normal
Condition
Control On On after successful completion of reset sequence ON
Control Fail On when a normal Baton control module failure is detected in the reset
sequence
OFF
Disable On when normal messaging activity is disabled OFF
Alarm On after station alarm is detected OFF
Distribution OK Not used Not used
GPS Lock On when satellite receiver locks on at least 3 satellites ON
RFB Req Not used Not used
TX OK On when transmitter is connected and ready to receive data
(Note: Controlled by transmitter only.)
ON