User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Installation
June 1999 6880497G01-B 4-13
Note: The green light-emitting diode (LED) on the AC power distribution unit indicates the surge
suppression is functional.
3. Place the AC Power Supply module Power switch in the ON position.
Repeat for all power supply modules (up to four).
Note: Any AC power in the ON position sources power to the RF-O! transmitter and
RF-B! transmitter controller chassis.
4. Place the RF-O! transmitter POWER switch in the ON (|) position.
All RF-O! transmitter LEDs light briefly during power up.
ON and Alarm are the only RF-O! transmitter LEDs lit after power-up self tests are
complete.
5. Place the RF-B! transmitter controller POWER switch to the ON position (|).
All seven RF-B! transmitter controller LEDs light briefly during power up (see
Figure 4-5).
All seven RF-B! transmitter controller LEDs turn off for 1 second.
All LEDs reflect normal operational conditions within 25 minutes (see Table 4-4).
Control On and Alarm are the only RF-B! transmitter controller LEDs still lit after
power-up self tests are complete.
Figure 4-5: RF-B! Transmitter Controller (Front View)
RESET
Control On
Control Fail
Disable
Alarm
Distribution OK
GPS Lock
RFB Req
TX OK
RF-Baton!™
Serial Port
705SRH-11
POWER
Controlled by
Transmitter Only
Power On/Off
Switch
RF-B! LEDs
Power
Seven RF-B!
Controlled