Environmental Specifications
The RF-B! transmitter controller requires special environmental conditions for proper
operation and system longevity (see Table 2-6).
Operating Specifications
RF-B! transmitter controller operating specifications are shown in Table 2-7.
Table 2-6: Environmental Specifications
Parameter Specification
Operating Temperature – 22 ˚F to 140 ˚F (–30
˚C to +60 ˚C) per TIA-603
Operating Humidity 0% to 95% relative at 122 ˚F (50
˚C) per TIA-603
Dust Airborne particles must not exceed 90 µg/m
3
Vibration TIA/EIA 603
Table 2-7: RF-B! Transmitter Controller Operating Specifications (Sheet 1 of 2)
Parameter Specification or Value
Host Processor Motorola 68EN360 running at 25 MHz
DSP Quad Motorola DSP56166 or DSP 56167 at 66 MHz
Memory 2 M x 32 bit DRAM on 72 pin SIMM
dual 512 k x 32 bit FLASH on 80 pin SIMM
32 k x 8 bit EEPROM socketed
Channel Capacity 1 to 4 subchannels of InFLEXion messaging protocol
3 subchannels of ReFLEX messaging protocol
Frame Time Synchronization GPS
Frequency Stability 5 ppb
Network Support Ethernet AUI
Optional 10Base2 transceiver available
Diagnostics Front panel FIPS using EIA-232 (3-wire connection)
Alarms System alarms supported using SNMP