User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
System Description RF-Baton! Transmitter Controller Installation and Operation
2-20 6880497G01-B June 1999
RF-Baton! Transmitter Controller Specifications
The RF-B! transmitter controller conforms to explicit mechanical, electrical, and
environmental specifications. The following sections discuss these specifications in detail.
Mechanical Specifications
The RF-B! transmitter controller is mechanically designed around specific parameters (see
Table 2-4). This design provides easy access to modules and interconnect points. The RF-B!
transmitter controller mounts in the same cabinet as the transmitter.
Electrical Specifications
The RF-B! transmitter controller operates within specific electrical parameters (see Table 2-5).
Table 2-4: RF-B! Transmitter Controller Mechanical Specifications
Parameter Specification
Standard mounting configuration 19 in. (48.26 cm) EIA cabinet
Width 19 in. (48.26 cm)
Height 2 rack units (3.5 in. or 8.89 cm)
Depth 15 in. (38.1 cm)
Weight 30 lb (13.64 kg)
Table 2-5: RF-B! Transmitter Controller Electrical Specifications
Parameter Specification
Input voltage +28 Vdc + or – 4Vdc
Input power 200 W max.
Input DC voltage ripple 50 mV p-p
FCC emission requirements Part 15
Lightning protection NA
Electrostatic discharge (ESD) In accordance with ETSI 300.279