User Manual

Table Of Contents
June 1999 6880497G01-B E-9
RF-Baton! Transmitter Controller Installation and Operation Traces
June 1999 6880497G01-B E-9
OPPM 0x00000001 1 OPP Manager Task Ethernet Statistics
Trace—details ethernet metrics as each
PDM is received by the RF-B!
transmitter controller.
UNICAST packets are PDMs directed at
a specific RF-B! IP.
MULTICAST packets are PDMs that are
broadcast to all RF-B!s.
OPPM: Rcvd 63 bytes
# PACKETS DISCARDED: 0
# ERROR PACKETS RECVD: 0
# PACKETS DISCARDED DUE TO UNKNOWN PROTOCOL: 0
# UNICAST PACKETS RECVD: 3747
# MULTIICAST PACKETS RECVD: 1497
OPPM 0x00000002 2
OPP Manager Task PDM Trace
verbosely displays the contents of each
PDM successfully received by the RF-B!.
NOTE: Paging Enable does NOT have to
be in effect for this trace to run. That is,
the ethernet front end is always
operational, regardless of the state of
paging.
This trace should be used sparingly on a
continuous basis because of the added
overhead in outputting the data.
PdmData { } = ReflexOpp
Time { } = 36 : 15 : 0
PdmApdu { } =
rfChannelIndex = 0
subchannel = 0
ReflexOpp { } =
Speed = 6400
Fsk = fsk4
PadBlocks = 10
DigEncoding = longWordWithBch
Fiw{} = cycle:9, frame:8, global:0, fr type:3, ch type:1
BIW #1 = end biw:6, end addr:6, co:0, mis:0
Additional BIW: CRC
Additional BIW: Zone ID
Additional BIW: Base Frame Mgmnt 2
Additional BIW: Rev Chnl Info
Additional BIW: SQC
TASK MASK
FLAG
(dec)
DESCRIPTION EXAMPLE OUTPUT