User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Alarms and Error Messages RF-Baton! Transmitter Controller Installation and Operation
D-2 6880497G01-B June 1999
E_PENDULUM_NOT_LOCKED The pendulum has fallen out of phase lock with the 10 MHz.
This could be due to the absence of a 10-MHz reference,
incorrect programming, failure of the RF-O! paging station
synthesizer, incorrect programming, or failure of the pendulum.
E_PENDULUM_REFERENCE_FAILURE The pendulum clock is no longer detectable by the host
microprocessor.
E_PLACE_BATCH_ON_PAGING_QUEUE Frame not added to paging queue.
E_PULSE_OUTSIDE_WIN_PAGING 1 PPS pulse occurred outside designated window.
E_SASM_FREERUN_TIMEOUT Global Positioning System (GPS) lock not re-acquired during
simulcast FREERUN. Paging is disabled until GPS lock is
re-acquired.
E_SASM_FREE_RUNNING SASM task is in free run state. Xilinx is running without 1PPS.
E_SUB_CHANNEL_DELETED AM subchannel message data was invalid.
E_TX_OK_DOWN TX_OK signal has been disabled by the transmitter.
E_UNABLE_TO_DETERMINE_SYS_CONFIG Unknown station controller type
E_UNMATCHED_ACTIVE_SUBCHNL_LAUNC
H_TIME
Launch time of pending message batch did not correspond with
the end time of current message batch on a unique subchannel.
E_XILINX_DOWNLOAD_FAILURE An error occurred while attempting to download a program to the
Field Programmable Gate Array (FPGA).
E_PULSE_OUTSIDE_WIN_PAGING 1 PPS pulse occurred outside designated window.
E_MISSING_AM_SIDEBAND One of the two sidebands of AM data was missing from a
message batch scheduled to be routed to the transmitter.
E_NO_DSP_AVAILABLE BCM ran out of available subchannels to transmit the data on.
E_MAIN_POWER_FAILURE Main power failure. Battery backup.
E_SW_DOWNLOAD_AND_INSTALL_FAIL TFTP software download or install failed.
Table D-1: Station Errors (Sheet 2 of 2)
Error Code Description