RF-Baton! Transmitter Controller Installation and Operation / Appendix D
June 1999 6880497G01-B D-1
Alarms and Error Messages D
This appendix presents the error messages and alarms for the RF-Baton! (RF-B!) transmitter
controller (see Table D-1 through Table D-7).
Table D-1 through Table D-3 list and describe the error codes that appear in the station error
log (a 104). Table D-4 through Table D-6 list and describe the error codes that appear in the
software event log (a 110). Table D-7 lists and describes the alarms. Once an error message is
generated, the associated alarm severity is modified by using the Friendly Interface Protocol
System (FIPS) action command, a 200 ?.
The tables are in alphabetical order by the Error Code column. Match the description below
with the message that appears in the log. Any modifications to the defaults listed below will
survive a station reset.
Table D-1: Station Errors (Sheet 1 of 2)
Error Code Description
E_DUPLICATE_MDP_FRAMES Duplicate frame detected in paging queue
E_EARLY_LAUNCH_TIME Single message data purged. The launch time is too far ahead
of the current time. Not enough RF-B! transmitter controller
memory.
E_FLUSH_PDM_LIST All message data purged. Data queues are flushed upon the
Baton Control Module (BCM) disabling paging.
E_HIGH_STABILITY_REFERENCE_FAILURE The station lost contact with the Ultra High Stability Oscillator
(UHSO).
E_LATE_LAUNCH_TIME Single message data purged. The necessary processing time
and current time exceeded the launch time.
E_MISSING_AM_SIDEBAND One of the two sidebands of AM data was missing from a
message batch scheduled to be routed to the transmitter.
E_NO_DSP_AVAILABLE BCM ran out of available subchannels to transmit the data on.
E_OPP_VERSION_NOT_SUPPORTED Unsupported OPP version.
E_PAGING_PROTOCOL_NOT_SUPPORTED Unsupported paging protocol.