702 Station ID High Reads the Upper 4 characters of the
station id
(use the a 59 command to read full
station id)
r 702 alpha-numeric n/a Y N N
703 Paging Protocol
Supported
Parameter to determine which protocol
will be decoded in the RF-B! transmitter
controller
r 703
w 703 [value]
1 = OPP
2 = CNET
(CNET not
supported)
1 = OPP Y Y N
704 Transmitter Color
Code
Parameter used to set InFLEXion
protocol “transmitter color code” in
outbound control information.
r 704
w 704 [value]
0 - 65535 21845 N N N
705 Network IP
Address
Parameter used to set IP address of
RF-B! transmitter controller.
r 705
w 705 [x.x.x.x]
where each x = 0
- 255
n/a N N N
706 Sub-Network Mask Parameter used to set IP sub-network
mask of RF-B! transmitter controller.
r 706
w 706 [x.x.x.x]
where each
x = 0 - $FF
0.0.0.0 N N N
707 User Password Password used to access FIPS r 707
w 707 [value]
[string] 6000 Y N N
708 Gateway Address Default gateway address r 708
w 708 [x.x.x.x]
where each
x = 0 - 255
0.0.0.0 N N N
800 UHSO Steering Value used to steer the UHSO
frequency - higher values result in lower
frequencies.
r 800
w 800 [value]
0 - 4095 2047 Y N N
Table C-2: Supported Parameters
Param
ID
Name Description Usage Range Default
Reset
with
DIP1 &
DIP2
Reset
with
DIP2
No
DIP