User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
C-20 6880497G01-B June 1999
FIPS Action Commands and Parameter IDs RF-Baton! Transmitter Controller Installation and Operation
C-20 6880497G01-B June 1999
502 SNMP Address2 Network address of SNMP manager 2. r 502
w 502
[xxx.xxx.xxx.xxx]
0YNN
503 SNMP Address3 Network address of SNMP manager 3. r 503
w 503
[xxx.xxx.xxx.xxx]
0YNN
504 SNMP Address4 Network address of SNMP manager 4. r 504
w 504
[xxx.xxx.xxx.xxx]
0YNN
600 FrequencyChange
Delay
Reads frequency change delay
PnP value
r 600 0 -999999 0 Y Y N
601 Key up Delay Reads transmitter key up delay
PnP value
r 601 0 - 999999 0 Y Y N
602 Workahead Time Reads Minimum workahead time
PnP value
r 602 0 - 999999 30000 Y Y N
603 Workahead
Window Width
Reads Workahead Window Width
PnP value
r 603 0 - 999999 50000 Y Y N
701 Station ID Low Reads the Lower 8 characters of the
station id
(use the a 59 command to read full
station id)
r 701 alpha-numeric n/a Y N N
Table C-2: Supported Parameters
Param
ID
Name Description Usage Range Default
Reset
with
DIP1 &
DIP2
Reset
with
DIP2
No
DIP