User Manual

Table Of Contents
June 1999 6880497G01-B C-19
RF-Baton! Transmitter Controller Installation and Operation FIPS Action Commands and Parameter IDs
June 1999 6880497G01-B C-19
346 OPP Multicast
Group Commit
Flag
Reads or Sets the OPP Multicast Group
Commit Flag. If “Group Write Mode”
(FIPS Parameter 347) is set to ‘1’
(Direct Write Mode), setting this flag has
no effect.
If “Group Write Mode” is set to ‘0’
(Gated Write Mode), setting this flag
updates the contents of the
entire
OPP
Multicast Configuration Table to the
Active Table.
r 346 (Read)
w 346 1 (Group
Commit
0YYN
347 OPP Multicast
Group Write Mode
Reads or Sets the OPP Multicast Group
Write Mode.
r 347 (Read)
w 347 [mode]
0 = Gated Write
Mode
1 = Direct Write
Mode
0YYN
430 Dormant download
status
Software download status of the
dormant bank
r 430 0 = fail
1 = pass
0 = fail Y Y N
500 SNMP Address0 Network address of SNMP manager 0. r 500
w 500
[xxx.xxx.xxx.xxx]
0YNN
501 SNMP Address1 Network address of SNMP manager 1. r 501
w 501
[xxx.xxx.xxx.xxx]
0YNN
Table C-2: Supported Parameters
Param
ID
Name Description Usage Range Default
Reset
with
DIP1 &
DIP2
Reset
with
DIP2
No
DIP