User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
C-16 6880497G01-B June 1999
FIPS Action Commands and Parameter IDs RF-Baton! Transmitter Controller Installation and Operation
C-16 6880497G01-B June 1999
Table C-2: Supported Parameters
Param
ID
Name Description Usage Range Default
Reset
with
DIP1 &
DIP2
Reset
with
DIP2
No
DIP
55 OPP Port Number Reads or sets the UDP Port Number r 55
w 55 [value]
0 - 65535 12000 N N N
99 Paging Access
Disabled
Parameter to show paging enabled or
disabled: 1= Disabled, 0 = Enabled
r 99
w 99 [value]
“0”= Enabled
“1” = Disabled
0YYN
136 Password verify Enable/Disable password verification r 135
w 135 <value>
1 = verify
password
2 = do not verify
password
1YY
N
136 FIPS time-out FIPS inactivity time-out value in
seconds
r 136
w 136 [value]
60 - 3600 300 Y Y N
139 FPSP Baud rate Reads or sets FIPS serial port
connection baud rate
r 139
w 139 [value]
1200 = 1
2400 = 2
4800 = 3
9600 = 4
19.2K = 5
38K = 6
57K = 7
115K = 8
4YYN