User Manual

Table Of Contents
June 1999 6880497G01-B C-9
RF-Baton! Transmitter Controller Installation and Operation FIPS Action Commands and Parameter IDs
June 1999 6880497G01-B C-9
177 Transmit Test Data Stop Stop transmission of canned
data to the OCM.
a 177 BCM stops sending data across the Plug-
n-Play interface.
Station stops transmitting data.
NOTE: Transmission of data may
immediately begin due to PDMs arriving at
the network interface; that is, normal
paging traffic.
192 Start Debug Trace Initiate trace to be displayed
using FIPS.
a 192 [TASK] [FLAG]
TASK = pSOS Task Name
GPSC, SASM
FIPS terminal begins displaying
information captured by software.
a 192 GPSC 8: Monitor GPS initialization
a 192 PCRM 4: Monitor PDMs information
a 192 SASM 34: Monitor Sync and
Simulcast
193 Stop Debug Trace Stop the trace using FIPS FLAG = Trace to disable a 193 GPSC 8
a 193 PCRM 4
194 Probe Mode Puts RF-B! transmitter
controller back into Probe
mode. This will cause the RF-B!
to cease normal operation
a 194 Probe should come up on probe port.
195 Set Subchannel Offsets Set the offset of the
subchannels relative to the
center frequency.
a 195 o1 o2 o3 o4
o1 = subchannel offset 1
o2 = subchannel offset 2
o3 = subchannel offset 3
o4 = subchannel offset 4
Range 1-16
Table C-1: FIPS Action Commands
Action Name Description Usage Response