User Manual

Table Of Contents
June 1999 6880497G01-B C-3
RF-Baton! Transmitter Controller Installation and Operation FIPS Action Commands and Parameter IDs
June 1999 6880497G01-B C-3
61 Configure a Multicast IP
Address
Adds a Multicast IP address to
the OPP Multicast
Configuration Table. If the
“Group Write Mode” (FIPS
param 347) is set to ‘1’ (Direct
Write Mode) the IP address
gets updated to the Active Table
as well.
a 61 i [
Multicast IP Address
]
i=1..16 is the index into the
Configuration Table where the
IP Address is to be added
Successful update or invalid IP Address
assertion.
99 Read All Alarms Display all alarms in alarm log. a 99
All alarms which have become active
since last clear-alarm-log command are
displayed. Format matches error log.
Supported alarms are listed in this
document. Full set of alarms is listed in
MPD.
103 Clear All Alarms Clear all alarms in alarm log. a 103 None. Re-reading alarm log will return no
alarms.
104 Read Error Log Display all errors in error log. a 104
All errors which have become active since
last clear-error-log command are
displayed. Errors are defined by software
developers to indicate failures related to
hardware or system problems. Error
format is: error -type, module in which
error was detected, line number in module,
time of last occurrence, number of
occurrences.
Table C-1: FIPS Action Commands
Action Name Description Usage Response