User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
RF-Baton! Transmitter Controller Installation and Operation Maintenance
June 1999 6880497G01-B 6-53
4. Set Switch 2 of Dual In-line Package (DIP) switch SW600 to ON (see Figure 6-12).
Figure 6-12: BCM Component Layout—DIP Switch S2 (SW600) Location
5. Gently place the BCM into the slot in the RF-B! transmitter controller chassis, firmly
seating the board card-edge connectors into the backplane (see Figure 6-11).
6. Set the RF-B! transmitter controller POWER switch to ON (|).
7. Allow the board to completely boot up (the FIPS prompt appears).
8. After the boot up, set the RF-B! transmitter controller POWER switch to OFF (O).
9. Gently pull the BCM straight out.
10. Set Switch 2 of DIP SW600 to OFF (see Figure 6-12).
302SRH-81a
SW600