User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
RF-Baton! Transmitter Controller Installation and Operation Maintenance
June 1999 6880497G01-B 6-31
Removal and Installation
Replace faulty FRUs with good FRUs to restore the RF-B! transmitter controller to proper
operation. The following procedures provide FRU removal and installation instructions.
Cabinet Doors
Perform the following procedures to remove and install the transmitter cabinet front or rear
door.
Doors Removal
Motorola recommends that two persons perform this procedure.
Note: One person supports the door while the other person detaches the hinges from the brackets.
1. Open the cabinet door.
2. On the bottom left of the door, compress the spring-loaded hinge pins until the hinge
pins clear the hinge bracket (see Figure 6-3).
Lock the pins in place.
CAUTION
The RF-B! transmitter controller contains static-sensitive modules. When servicing
the equipment, you must take precautionary steps to prevent damage to the modules
from static discharge.
Do not force RF-B! transmitter controller modules into their slots. Connector damage
can occur if the modules are not carefully inserted.