User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Maintenance
June 1999 6880497G01-B 6-23
Verify Data to Transmitter
The final step in the data path through the RF-B! transmitter controller is the data router. This
procedure checks the data router to verify the proper transfer of data to the transmitter.
1. Connect your FIPS terminal to the FIPS Serial Port on the front panel of the RF-B!
transmitter controller and log into the FIPS session (see Chapter 5, "Operation",
paragraph, "Service Terminal").
2. Enable the Data Router (DRT1) output trace.
At the prompt, type:
a 192 DRT1 1 <Enter>
The terminal displays the DRT1 1 trace.
Verify that the inc value and the delta value are identical to the values shown in this trace
example. If the values are not identical with those shown, call one-call support.
Note: If this occurs, no user servicable solution exists. The problem is a Plug n Play (PnP) problem.
3. Stop the trace.
At the prompt, type:
a 193 DRT1 1 <Enter>
The trace stops and the terminal displays:
RFB FIPS: RA 193
DRTR1: inc=152 delta=152 mod=0 id=82EE54C
DRTR1: inc=9 delta=9 mod=0 id=825C54C
DRTR1: inc=2 delta=2 mod=0 id=827A54C
DRTR1: inc=9 delta=9 mod=0 id=8247B4C
DRTR1: inc=2 delta=2 mod=0 id=827C54C
DRTR1: inc=9 delta=9 mod=0 id=825A74C