Maintenance RF-Baton! Transmitter Controller Installation and Operation
6-16 6880497G01-B June 1999
8. Stop the ethernet statistics trace.
At the prompt, type:
a 193 OPPM 1 <Enter>
The trace stops and the terminal displays:
RFB FIPS: RA 193
Verify RF-B! Transmitter Controller Paging Is Enabled
Since the OPP manager is processing input message data (verified in the previous section),
verify that the RF-B! transmitter controller has enabled paging. There are three conditions
which must be satisfied in order for paging to be enabled. They are:
The user has not manually disabled paging through FIPS.
The Simulcast manager is in a paging state.
The system hardware manager has not detected an error.
1. Connect your FIPS terminal to the FIPS Serial Port on the front panel of the RF-B!
transmitter controller and log into the FIPS session (see Chapter 5, "Operation",
paragraph, "Service Terminal").
2. Verify that paging is enabled.
At the prompt, type:
a 192 PCRM 2 <Enter>
The trace displays the paging status of the RF-B! transmitter controller. For example:
Paging is Enabled!
3. Stop the trace.
At the prompt, type:
a 193 PCRM 2 <Enter>
The trace stops and the terminal displays:
RFB FIPS: RA 193
4. If paging is enabled, go to paragraph, "Verify Launch Time Calculation and Processing".
If paging is disabled, proceed with Step 5.