User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Maintenance
June 1999 6880497G01-B 6-15
7. Verify that the ethernet packets are not being rejected
.
If the number of discarded packets is close or equal to the number of received packets,
the problem is in the ethernet. Refer to the site networking documentation to
troubleshoot the RF-C! controller to RF-B! transmitter controller network connection.
If the number of discarded packets is equal to zero and the OPPM 4 trace was blank, the
problem is in the RF-C! controller. Refer to RF-Conductor!™ Controller Hardware
Installation
, Motorola Part No. 6880494G50 or RF-Conductor!™ Controller Installation,
Motorola Part No. 6880494G53 to troubleshoot the problem. Be sure to check the RF-B!
transmitter controller IP address and port number resident in the RF-C! controller.
====================================================
OPPM: Rcvd 10312 bytes
# PACKETS DISCARDED: 0
# ERROR PACKETS RECVD: 1
# PACKETS DISCARDED DUE TO UNKNOWN PROTOCOL: 0
# UNICAST PACKETS RECVD: 2424
# MULTIICAST PACKETS RECVD: 401 255
====================================================
OPPM: Rcvd 64 bytes
# PACKETS DISCARDED: 0
# ERROR PACKETS RECVD: 1
# PACKETS DISCARDED DUE TO UNKNOWN PROTOCOL: 0
# UNICAST PACKETS RECVD: 2432
# MULTIICAST PACKETS RECVD: 401
====================================================