User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Maintenance RF-Baton! Transmitter Controller Installation and Operation
6-14 6880497G01-B June 1999
Table 6-2 shows the Paging Data Message (PDM) data types for the OPPM packet trace.
4. Go to paragraph, "Verify RF-B! Transmitter Controller Paging Is Enabled".
5. Stop the network packet trace.
At the prompt, type:
a 193 OPPM 4 <Enter>
The trace stops and the terminal displays:
RFB FIPS: RA 193
If there is no trace output for the OPPM 4 network packet trace continue with Step 6
through Step 8.
6. Enable the ethernet statistics trace.
At the prompt, type:
a 192 OPPM 1 <Enter>
This trace displays the ethernet statistics correlating to the input data.
Table 6-2: PDM Data Types for the OPPM Packet Trace
PdmData Type Modulation Mode Description
InflexionSynch Frequency Modulation (FM) 90 ms packet
ReflexOpp FM 1.875 second data packet
PilotOnly Amplitude Modulation (AM) 20 ms, packet.
InflexionSqm AM 1-3 patterns, 30 ms each packet
InflexionAdpcm24 AM May occur many times in a single AM packet, but
must occur in pairs
(SideBandMode =0,1)