User Manual

Table Of Contents
Maintenance RF-Baton! Transmitter Controller Installation and Operation
6-8 6880497G01-B June 1999
HIGH_STABILITY_REFERENCE_FAILURE
To correct a HIGH_STABILITY_REFERENCE_FAILURE, perform the following procedure:
1. Clear the error log.
At the prompt, type:
a 111 <Enter>
2. Set the RF-B! transmitter controller power switch to Off (O).
3. Remove the faceplate (see paragraph, "Faceplate Removal").
4. Reseat the BCM and Reference module into the backplane to ensure they are inserted
properly.
Slide the boards out one or two inches and then carefully push them into the backplane
connectors.
5. Install the faceplate (see paragraph, "Faceplate Installation").
6. Set the RF-B! transmitter controller power switch to On (|).
7. View the error log.
At the prompt, type:
a 104 <Enter>
If the <E_HIGH_STABILITY_REFERENCE_FAILURE> is in the log, the 10 MHz reference
signal is missing.
8. Check the 10 MHz coaxial cable for loose or broken connectors.
If the cable is bad, replace the cable.
9. If the cable is good, replace the reference module.
10. If the reference module is good, replace the DC-DC converter.