User Manual

Table Of Contents
Maintenance RF-Baton! Transmitter Controller Installation and Operation
6-4 6880497G01-B June 1999
6. If the paging mode is disabled, enable paging.
At the prompt, type:
w990<Enter>
7. List the Errors that have been logged.
At the prompt, type:
a 104 <Enter>
The terminal displays the error messages that have been generated since the last reset.
Error messages are described in Appendix D.
8. Compare the message launch times against the pSOS system time using the input paging
data QUEUE trace command.
At the prompt, type:
a 192 PCRM 4 <Enter>
The terminal displays the QUEUE trace.
9. Stop the input paging data QUEUE trace.
At the prompt,type:
a 193 PCRM 4 <Enter>
10. Stop the trace.
At the prompt, type:
a 193 PCRM 4 <Enter>
The trace stops and the terminal displays:
RFB FIPS: RA 193