RF-Baton! Transmitter Controller Installation and Operation Maintenance
June 1999 6880497G01-B 6-3
RF-B! Transmitter Controller Status
Use the following steps to check the status of the RF-B! transmitter controller using the service
terminal interface.
1. Connect your Friendly Integrated Paging System (FIPS) terminal to the Serial port on the
front panel of the RF-B! transmitter controller and log into the FIPS session (see
Chapter 5, "Operation", paragraph, "Service Terminal").
Note: The alarm and error logs provide detailed diagnostic information.
2. Display the alarms that have been generated.
At the prompt, type:
a99<Enter>
The terminal displays the alarms that have been generated since the last reset. The alarms
are described in Appendix D.
3. Alarms are normally logged to the Choreographer! network manager using Simple
Network Management Protocol (SNMP). If the alarms are not being displayed on the
Choreographer! network manager, check the value of the Choreographer! network
manager Internet Protocol (IP) address programmed into the RF-B! transmitter controller.
At the prompt, type:
r 500 <Enter>
The terminal displays the Choreographer! network manager IP address.
4. Correct an invalid IP address.
At the prompt, type:
w 500 [xxx.xxx.xxx.xxx] <Enter> (where xxx.xxx.xxx.xxx is the Choreographer! network
manager IP address)
5. Verify the state of the RF-B! transmitter controller paging mode.
At the prompt, type:
r99<Enter>
The terminal displays the paging mode: (0=Enabled, 1=Disabled).