User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Maintenance RF-Baton! Transmitter Controller Installation and Operation
6-2 6880497G01-B June 1999
Alarm LED lit Station alarm has been detected Interrogate error log, alarm log, or both
Distribution OK LED lit Not used
GPS LED not lit
(more than 1 hr.)
No GPS; GPS in test mode; GPS antenna
blocked, bad location, or both
Reset control module, unblock GPS
antenna, check antenna location (see,
paragraph, "GPS Diagnostics").
RFB Req LED not lit Not used Not used
TX OK LED not lit Transmitter not hooked up Connect transmitter to RF-B! transmitter
controller
Bad transmitter cable Replace transmitter to RF-B! transmitter
controller cable.
Improper transmitter configuration. Refer to
RF-Orchestra! Paging Station
Installation and Operation
, Motorola Part
No. 6880493G02.
RF-B! fails to
complete power-up
reset
Bad DRAM or Flash SIMM See paragraph, "Bad DRAM or Flash
SIMM".
RF-B! not keying
transmitter
RF-B! data path problem
Networking or RF-C! disconnect
RF-B! to RF-O! miscommunication
RF-O! paging not enabled
RF-B! paging not enabled
RF-B! or RF-O! PnP error
See paragraph, "Data Path Diagnostics".
Table 6-1: Control Module Troubleshooting Chart (Sheet 2 of 2)
Indication Possible Failure Corrective Action