5-30 6880497G01-B June 1999
Log Initialization
This section shows the initial condition of the station alarm and station error logs after a
power-on reset. Since neither log is maintained through a power-on reset, these logs show the
alarms and error messages that are logged during a normal RF-B! transmitter controller
initialization.
Initial Alarm Log
The following is the alarm log during GPS receiver initialization. Paging is disabled until the
GPS and simulcast initialization are complete.
Once the GPS and simulcast initialization is complete, paging is enabled. This is shown by the
STATUS of the “Paging is disabled” alarm changing to “OK”
AL = the alarm is in effect
OK = the alarm is cleared (not in effect)
The initial alarm log should be cleared after GPS initialization is complete, using the FIPS a
103 action command, so that the front panel ALARM LED is an indicator of when new
operational alarms are logged.
ALARM STATUS COUNT DESCRIPTION
arst AL 001 Alarm occurred on Reset
pgds AL 001 Paging is disabled
ALARM STATUS COUNT DESCRIPTION
arst AL 001 Alarm occurred on Reset
pgds OK 001 Paging is disabled