User Manual

Table Of Contents
RF-Baton! Transmitter Controller Installation and Operation Operation
June 1999 6880497G01-B 5-29
3. To clear the station error log.
At the prompt, type:
a 111 <Enter>
Clears the station error log.
The station error log is maintained during hard and software resets.
Software Error Log
This log is used primarily for development debugging purposes and does not contain any
operational errors. To read the current software log, perform the following steps:
1. Establish a FIPS session (see paragraph, "Service Terminal").
2. Use the following command to read all alarms.
At the prompt, type:
a 110 <Enter>
Lists the current software log.
Note: The software log does not contain any operational errors.
3. Use the following command to clear the log.
At the prompt, type:
a 113 <Enter>
The software log is maintained during a hard and software reset.