User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
Operation RF-Baton! Transmitter Controller Installation and Operation
5-20 6880497G01-B June 1999
Note: The 1600 bps bit rate is only available with 2-level FSK
For more details on supported test transmission options, see the description of FIPS
action command 176 in Appendix C.
Note: Ensure that the distribution network is reconnected when the test is complete, so normal
processing can resume.
2. When the test is complete, disable the test mode.
At the prompt, type.
a 177 <Enter>
The test transmission ends immediately, and normal processing resumes.
Note: The test modes provided for checking-out and troubleshooting a messaging station with no
distribution network connection is available.
Table 5-8: Data Bit Rate Index
Bit Rate Index Bit Rate
2 1600 bps
4 3200 bps
5 6400 bps
Table 5-9: FM FSK Index
FSK Index FSK Level
0 2-level
1 4- level