User Manual
Table Of Contents
- Foreword
- PSG Limited Equipment Warranty for U.S. And Canadian Markets
- PSG Limited Equipment Warranty for NonU.S. and Non-Canadian Markets
- Introduction 1
- System Description 2
- The Wireless Messaging System Overview
- FLEX, ReFLEX and InFLEXion Messaging Protocol Overview
- RF-B! Transmitter Controller Functional Description
- RF-Baton! Transmitter Controller Specifications
- Preinstallation 3
- Installation 4
- Operation 5
- Maintenance 6
- Troubleshooting
- Data Path Diagnostics
- GPS Diagnostics
- Removal and Installation
- Assigning an RF-B! Transmitter Controller to a Multicast Group
- Remote Software Download from Choreographer! Network Manager
- Local Software Download Using the Front Panel
- Parameter Database Updating
- Abbreviations and Acronyms A
- Connector Pinouts B
- FIPS Action Commands and Parameter IDs C
- Alarms and Error Messages D
- Traces E
RF-Baton! Transmitter Controller Installation and Operation Operation
June 1999 6880497G01-B 5-7
Changing the Serial Port Baud Rate
The FIPS serial port connect baud rate is accessed using FIPS parameter 139. The factory
default value of this parameter is 9600 bits per second (bps).
For example; to change the baud rate of the serial connection to 4800 bps:
At the prompt, type:
w 139 3 <Enter>
(The input baud rate parameter comes from Table 5-3.)
The system responds:
RFB FIPS: RW 139 3
Note: Be sure to change the baud rate of the terminal emulation program to correspond with the FIPS
baud rate
Table 5-3: Serial Port Baud Rate Parameters
Baud Rate
Parameter
Baud Rate
1 1200 bps
2 2400 bps
3 4800 bps
4 9600 bps
5 19.2 kbps
6 38 kbps
7 57 kbps
8 115 kbps