User Manual

Table Of Contents
Operation RF-Baton! Transmitter Controller Installation and Operation
5-6 6880497G01-B June 1999
Customizing FIPS
The following procedures customize your FIPS sessions for a specific RF-B! transmitter
controller.
Changing the FIPS Password
To enter a terminal session using FIPS, you must enter a password. The factory default FIPS
password is 6000 but may be changed for greater security. Access the password through FIPS
parameter 707. For example; to change the password to baton, type:
w 707 baton <Enter>
The system responds:
RFB FIPS: RW 707 baton
Note: Resetting the parameter database resets the FIPS password to the factory default.
Changing the FIPS Inactivity Time-out
If a period of time elapses without activity at the FIPS port, the RF-B! transmitter controller
FIPS session times out and requires the user to re-enter a password. These actions do not affect
paging operation.
The factory default FIPS inactivity time-out is 300 seconds. The inactivity time-out is accessed
using FIPS parameter 136. For example; to change the inactivity time-out to 1800 seconds (30
minutes), type:
w 136 1800 <Enter>
The system responds
RFB FIPS: RW 136 1800
Note: Resetting the parameter database resets the FIPS inactivity timeout to the factory default.